Experimental Investigation on Pool Boiling Heat Transfer to Formic Acid, Propanol and ۲-Butanol Pure Liquids under the Atmospheric Pressure

Publish Year: 1392
نوع سند: مقاله ژورنالی
زبان: English
View: 216

This Paper With 7 Page And PDF Format Ready To Download

  • Certificate
  • من نویسنده این مقاله هستم

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این Paper:

شناسه ملی سند علمی:

JR_JAFM-6-1_008

تاریخ نمایه سازی: 5 بهمن 1400

Abstract:

In this research, pool boiling heat transfer coefficient values were experimentally measured up to heat flux ۱۱۵kW.m-۲. Experiments were carried out for pool boiling of pure liquids, including of Formic acid, Propanol, ۲-butanol on a horizontal smoothed cylinder, at atmospheric pressure. Applicability of the existing well-known and most common used correlations is comparatively discussed, with the present experimental data. The major predictions (over and/or under) were observed in some parameter range by the existing correlations. In this investigation the correlations of Stephan Abdelsalam, Boyko-Kruzhilin and Mostinski, have been compared with experimental data.

Authors

M. M. Sarafraz

Department of Chemical Engineering, Mahshahr branch, Islamic Azad University, Mahshahr, Iran