Mechanism and Prevention of Scale Formation in Boilers
Publish place: International Journal of Engineering (IJE)، Vol: 6، Issue: 1
Publish Year: 1372
نوع سند: مقاله ژورنالی
زبان: English
View: 102
This Paper With 7 Page And PDF Format Ready To Download
- Certificate
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_IJE-6-1_001
تاریخ نمایه سازی: 19 اسفند 1400
Abstract:
Nucleate boiling heat transfer coefficients may be strongly reduced by scale formation, even for conditions where the bulk foulant concentration is well below the saturation concentration. Due to the mechanism of micro-layer evaporation, the local concentration at the heat transfer surface can be considerably increased, causing the formation of scale and changes in bubble frequency and bubble departure diameter. The interaction between scale formation and bubble formation is studied with a precision pool boiling test apparatus in conjunction with a microprocessor-controlled camera and video equipment. The effects of EDTA which is commonly used as an antifouling agent in industrial boilers, on saturated pool boiling in the presence of foulants are discussed.
Keywords:
Authors
H. MulIer-Steinhagen
Chemical & Petroleum Engineering, University of Surrey