Performance Analysis of K out of N Reverse Osmosis (RO) system in the treatment of wastewater using RAMD analysis

Publish Year: 1400
Type: Journal paper
Language: English
View: 224

This Paper With 9 Page And PDF Format Ready To Download

Export:

Link to this Paper:

Document National Code:

JR_IJRRS-4-1_011

Index date: 14 March 2022

Performance Analysis of K out of N Reverse Osmosis (RO) system in the treatment of wastewater using RAMD analysis abstract

The recursive approach for assessing the reliability, availability, maintainability, and dependability (RAMD) of five subsystems in a reverse osmosis (RO) machine was investigated in this study. The components include the raw water tank, precision filter, carbonated filter, reverse osmosis membrane, and water producing tank. Furthermore, the efficacy of a reverse osmosis (RO) unit, mean time to failure (MTTF), mean time to repair (MTTR), and dependability ratio were also assessed. The major aim is to maximize efficiency and identify the critical subsystem or component of the reverse osmosis machine. And finding out how to fix the problem. We utilized data from the RO unit with a repair rate and a failure rate over a 100-day period to validate the technique. There were numerical numbers for each subsystem's dependability, as well as comparisons between subsystem dependability and total system dependability.

Performance Analysis of K out of N Reverse Osmosis (RO) system in the treatment of wastewater using RAMD analysis Keywords:

Performance Analysis of K out of N Reverse Osmosis (RO) system in the treatment of wastewater using RAMD analysis authors

Anas Maihulla

Department of Mathematics, Faculty of Science, Sokoto state University, Sokoto. Nigeria

Ibrahim Yusuf

Department of Mathematical sciences, Faculty of physical sciences, Bayero University, kano

Saminu Bala

Department of mathematical sciences, Faculty of physical sciences, Bayero University, Kano