The Effect of Cobalt Oxide Nanoparticles on Improving the Quality of Computerized Tomography (CT) Scan Medical Imaging
Publish place: Iranian Journal of Medical Physics، Vol: 19، Issue: 3
Publish Year: 1401
نوع سند: مقاله ژورنالی
زبان: English
View: 149
This Paper With 5 Page And PDF Format Ready To Download
- Certificate
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_IJMP-19-3_003
تاریخ نمایه سازی: 25 خرداد 1401
Abstract:
Introduction: Sometimes, a patient receives a poor quality medical image from a medical imaging center. Which the doctor orders to re-image with a drug contrast media agent. At this time, practical action is challenging to provide a proper image. Cobalt oxide nanoparticles show different activities based on different sizes and shapes. Objectives of this project is achievement a critical size of cobalt oxide nanoparticles between ۵ to ۱۰ nanometers for easy circulation in the blood and Investigation of the effect of cobalt oxide nanoparticles on the quality of CT from laboratory mice(Mus musculus).Material and Methods: In this study, the coupling method was used to prepare the cobalt oxide nanoparticles. Co۳O۴ nanoparticle coatings are used for this purpose. They were investigated through the Fourier-transform infrared (FTIR) analysis, X-rays diffraction (XRD). In order to investigate the efficacy of cobalt oxide nanoparticles, we injected a suspension into the Mus musculus, and then the computerized tomography (CT) scans were taken before and after injection of the nanoparticles. Then, quantity evaluation was performed using the calculating the average local contrast media of the whole image.Results: The average size of cobalt oxide nanoparticles was obtained about ۵.۸ nm, which is an appropriate size in the nanometer scale. After injecting of cobalt oxide nanoparticles into the mice and then CT scan imaging, we have obtained a better clarity.Conclusion: Cobalt oxide nanoparticles behave well for use as a pharmacological contrast media agent in CT scan imaging.
Keywords:
Contrast Media Neoplasms Nanoparticles Computerized Tomography X , Rays
Authors
Mohamdreza Armanmehr
Department of Physics, Payam Noor University (PNU), Tehran, Iran
Mohammadreza Jalali
Department of Physics, Payam Noor University (PNU), Tehran, Iran
Ali Asghar Shokri
Department of Physics, Payam Noor University (PNU), Tehran, Iran
Ali Heydari Chaleshtori
Department of Biomedical Engineering, Payam Noor University (PNU), Tehran, Iran
مراجع و منابع این Paper:
لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :