Comparison of Patient-Specific Quality Assurance of ۶ MV and ۱۰ MV VMAT plan at Isocenter using Improved Gamma Evaluation Algorithm
Publish place: Iranian Journal of Medical Physics، Vol: 19، Issue: 5
Publish Year: 1401
نوع سند: مقاله ژورنالی
زبان: English
View: 115
This Paper With 8 Page And PDF Format Ready To Download
- Certificate
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_IJMP-19-5_004
تاریخ نمایه سازی: 2 مهر 1401
Abstract:
Introduction: To compare Patient-Specific Quality Assurance (PSQA) of ۶ MV and ۱۰ MV Volume Modulated Arc Therapy (VMAT) plans performed with Electronic Portal Imaging Device (EPID) kept at Isocenter ۱۰۰ cm (Source to Imager Distance (SID)) using an Improved Gamma Evaluation algorithm. Material and Methods: Previously treated patients with ۶ MV IMRT for Pelvic cancers were planned, on Eclipse TPS, with ۶ MV and ۱۰ MV photon beams using VMAT technology. The PSQA was performed using EPID and investigated the effect on Area Gamma, Maximum Gamma & Average Gamma. Results: The mean Area Gamma passing rate (%GP±Standard Deviation(σ)) for ۶ MV was ۹۷.۰۶±۳.۷۰, ۹۵.۴۲±۵.۳۱, ۹۰.۹۳±۷.۲۹, ۸۶.۵۵±۹.۱۰ and for ۱۰ MV ۹۷.۱۴±۶.۰۸, ۹۵.۸±۸.۴۷, ۹۴.۶۲±۹.۴۵, ۹۱.۹۷±۱۳.۵۰ using the criteria ۳%/۳ mm, ۳%/۲ mm, ۲%/۳ mm, ۲%/۲ mm respectively. Similarly, for mean Maximum Gamma value for ۶ MV was ۲.۵۰±۰.۸۹, ۲.۷۲±۰.۹۴, ۳.۳۲±۱.۱۳, ۳.۵۶±۱.۰۲ and for ۱۰ MV ۲.۱۷±۰.۶۲, ۲.۴۲±۰.۷۲, ۲.۸۴±۰.۹۰, ۳.۲۶±۰.۹۴ respectively. For mean average gamma, value for ۶ MV was ۰.۳۶±۰.۰۹, ۰.۴۲±۰.۱۰, ۰.۴۵±۰.۱۲, ۰.۵۳±۰.۱۳ and for ۱۰ MV was ۰.۲۷±۰.۱۶, ۰.۳۲±۰.۱۹, ۰.۳۴±۰.۲۰, ۰.۴۱±۰.۲۴. Conclusion: There is a marked difference between Area Gamma Passing Rate of ۶ MV and ۱۰ MV photon beam. The gamma criteria of ۳%/۲ mm with a ۵% Threshold limit and ۹۵% Area Gamma Passing Rate can be used for PSQA using EPID at Isocenter for ۶ MV and ۱۰ MV photon beam. There is no marked significant difference in values of mean Maximum Gamma and mean Average Gamma for ۶ MV and ۱۰ MV photon beams PSQA
Keywords:
Authors
JITENDRA NIGAM
DEPARTMENT OF PHYSICS, INVERTIS UNIVERSITY, BAREILLY, UP, INDIA
Piyush Kumar
RADIATION ONCOLOGY, SHRI RAM MURTI SMARAK INSTITUTE OF MEDICAL SCIENCES, BHOJIPURA, BAREILLY ۲۴۳۲۰۲
P SINGH
Dean, Faculty of Science Invertis University Bareilly-۲۴۳ ۱۲۳ (U.P.) India
مراجع و منابع این Paper:
لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :