The Ability of Ultrasonic Characterization to Extract the Dose Distribution of MAGIC-f Polymer Gel abstract

Background & Aims: Today, different imaging techniques have been studied in the reading of radiationsensitive polymer gels dosage. Due to limitations of imaging techniques such as magnetic resonance imaging (MRI) and computed tomography (CT), ultrasound techniques are proposed for dose-dependent parameter extraction. In this study, using MAGIC-f (methacrylic and ascorbic acid in gelatin initiated by copper with added formaldehyde) polymer gel and megavoltage radiation energy, the dose-dependent parameters of speed of sound and broadband ultrasonic attenuation (BUA) were evaluated. Methods: MAGIC-f polymer gel was irradiated with 1.25 MeV of Cobalt-60 and received a uniform dose in the range of 0 to 60 Gy in 2 Gy steps (2% accuracy). After calibration of ultrasound system with 500 kHz frequency, the parameters of speed of sound and BUA coefficient of exposed polymer gel samples were measured. Based on the dose-response curve, the ability of the ultrasound parameters in reading the absorbed dose was investigated. To evaluate the reasonable time interval with the most sensitive reading of the ultrasound method, samples were studied 3, 24, 36, and 48 hours after irradiation. To study the temperature readings, the gel samples irradiated at 5, 15, and 25 °C were studied. Results: The relationship of variation of speed of sound and attenuation coefficient and quality index (QI) with absorbed dose 3, 24, 36, and 48 hours after irradiation of gels are shown with a fourth-order polynomial fit. The results show that ultrasonic parameters have higher sensitivity 24 hours after irradiation. The sensitivity of dose-speed of sound and attenuation curve were 50 cm/s and 0.06 dB/MHz/Gy based on each Gy in the linear range of 4-44 Gy. Ultrasonic parameters were measured in the gel samples at 5, 15, and 25 ºC after 0-60 Gy irradiation in 2 Gy steps to determine the sensitivity of the ultrasonic properties to temperature. The measurements show that readings at 25 °C have a higher sensitivity than that at 5 and 15 °C. Thus, with an increase of 20 °C, the speed of sound increased 28 and 66 m/s before irradiation and with 60 Gy absorbed dose, respectively. Moreover, the attenuation coefficient decreased 2.50 dB/MHz before irradiation and increased 2.70 dB/MHz with 60 Gy absorbed dose. Conclusion: Acoustic properties of MAGIC-f gel, determined by measurements of speed of sound and ultrasonic broadband attenuation, indicate the ability of this technique in reading of absorbed dose. Maximum sensitivity of reading time and temperature of MAGIC-f gel were 24 hours after irradiation and 25 °C, respectively

The Ability of Ultrasonic Characterization to Extract the Dose Distribution of MAGIC-f Polymer Gel Keywords:

The Ability of Ultrasonic Characterization to Extract the Dose Distribution of MAGIC-f Polymer Gel authors

Hossein Masoumi

Ph.D. Student, Department of Medical Physics, School of Medical Sciences, Tarbiat Modares University, Tehran, Iran

Manijeh Mokhtari-Dizaji

Professor, Department of Medical Physics, School of Medical Sciences, Tarbiat Modares University, Tehran, Iran

Azim Arbabi

Professor, Department of Radiotherapy and Oncology, School of Medical Sciences, Shahid Beheshti University of Medical Sciences, Tehran, Iran

Mohsen Bakhshandeh

Assistant Professor, Department of Radiology Technology, School of Allied Medical Sciences, Shahid Beheshti University of Medical Sciences, Tehran, Iran

مراجع و منابع این Paper:

لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :
Khan FM. The physics of radiation therapy. ۴th ed. Philadelphia, ...
Gore JC, Kang YS, Schulz RJ. Measurement of radiation dose ...
Maryanski MJ, Schulz RJ, Ibbott GS, Gatenby JC, Xie J, ...
News from Yale Medical SchoolandHarvard Cyclotron Laboratory. Three dimensional dose ...
De DY, De WC, Van DB, Derycke S, Mersseman B, ...
Haraldsson P, Back SA, Magnusson P, Olsson LE. Dose response ...
De DY, Hurley C, Venning A, Vergote K, Mather M, ...
Baldock C, Burford RP, Billingham N, Wagner GS, Patval S, ...
Baldock C, Rintoul L, Keevil SF, Pope JM, George GA. ...
Sittig M. Handbook of toxic and hazardous chemicals and carcinogens. ...
McJury M, Oldham M, Cosgrove VP, Murphy PS, Doran S, ...
Fong PM, Keil DC, Does MD, Gore JC. Polymer gels ...
De DY, Vergote K, Claeys C, De WC. The fundamental ...
Hurley C, Venning A, Baldock C. A study of a ...
Luci JJ, Whitney HM, Gore JC. Optimization of MAGIC gel ...
Adinehvand K, Zahmatkesh M, Aghamiri M, Akhlaghpour S, Bagheri S. ...
Fernandes JP, Pastorello BF, de Araujo DB, Baffa O. Formaldehyde ...
Mather ML, De DY, Whittaker AK, Simon GP, Rutgers R, ...
Marini G, Pavan T, Baggio A, Carneiro A. Doppler images ...
Chu KC, Jordan KJ, Battista JJ, Van DJ, Rutt BK. ...
Hilts M, Audet C, Duzenli C, Jirasek A. Polymer gel ...
Hilts M, Jirasek A, Duzenli C. Effects of gel composition ...
Trapp JV, Back SA, Lepage M, Michael G, Baldock C. ...
Trapp JV, Michael G, De DY, Baldock C. Attenuation of ...
Oldham M, Siewerdsen JH, Shetty A, Jaffray DA. High resolution ...
Novotny J, Jr., Spevacek V, Dvorak P, Novotny J, Cechak ...
De DY, Venning A, Hurley C, Healy BJ, Baldock C. ...
Karlsson A, Gustavsson H, Mansson S, McAuley KB, Back SA. ...
Crescenti RA, Bamber JC, Bush NL, Webb S. Characterization of ...
Mather ML, Whittaker AK, Baldock C. Ultrasound evaluation of polymer ...
Atkins TJ, Humphrey VF, Duck FA, Tooley MA. Investigation of ...
Njeh CF, Blake GM. Calcaneal quantitative ultrasound devices. In: Fuerst ...
Crescenti RA, Bamber JC, Oberai AA, Barbone PE, Richter JP, ...
Maryanski MJ, Zastavker YZ, Gore JC. Radiation dose distributions in ...
نمایش کامل مراجع