Abstract:
This paper demonstrates the high-potential energy saving of heat integrated distillation column (HIDiC) for industrial methanol-water separation, which has huge energy consumption because of its high purity products specifications. Effects of prevalent uniform heat distribution scenario on HIDiC’s Total EnergyConsumption (TEC) have been investigated. An optimum heat transfer duty based on the mentioned scenario is introduced. Calculation for comparisonbetween HIDiC and conventional distillation column is based on Total Annual Cost (TAC). The results show 30% reduction in TAC and 60% reduction in TEC forHIDiC versus conventional distillation columns, although HIDiC has two expensive devices; compressor and heat panel. Promising future will be anticipated for HIDiCs in industrial scale.
Authors
H Shahandeh
Computer Aided Process Engineering Laboratory, Chemical Engineering Department, Iran University of science & technology, Tehran, Iran
مراجع و منابع این Paper:
لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :