SEISMIC RETROFITTING OF A 7-STORY R.C. BUILDING
Publish Year: 1386
نوع سند: مقاله کنفرانسی
زبان: English
View: 1,321
This Paper With 8 Page And PDF Format Ready To Download
- Certificate
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
SEE05_534
تاریخ نمایه سازی: 25 شهریور 1385
Abstract:
Add of concentric steel bracings is a simple and adequate method for retrofitting of existing moment frame R.C. buildings. Because any other retrofitting methods ( including add of shear walls or FRP ) seems to be very expensive. But concentric steel bracings have high stiffness, low ductility and sometimes cause architectural problems in buildings. Hence, the arrangement of these bracings must be studied exactly and
then the optimum retrofitting method is selected. In this paper, vulnerability studies and retrofitting method of a 7-story R.C. building with medium moment frame system, in Semnan city is investigated. This building, because of low height of its beams and according to 3rd edition of standard No. 2800, is a flat slab system and must be retrofitted. In the other hand, with adding steel bracings at different levels of existing R.C. building
and with regard to structural performance levels, the optimum retrofitting method must be selected. Nonlinear static analyses (push-over) are carried out according to FEMA-356 and ATC-40, and criteria of rehabilitation standard studied. Details of retrofitted elements are presented too.
Authors
Hemmati
Lecturer, Department of Civil Engineering, Islamic Azad University, Semnan Branch, Iran
Kheyroddin
Associate Professor, Department of Civil Engineering, Semnan University, Iran
مراجع و منابع این Paper:
لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :