Analysis and Simulation of Load Frequency Control in Power System with Reheater Steam Turbine

Publish Year: 1401
نوع سند: مقاله ژورنالی
زبان: English
View: 88

This Paper With 7 Page And PDF Format Ready To Download

  • Certificate
  • من نویسنده این مقاله هستم

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این Paper:

شناسه ملی سند علمی:

JR_JADSC-5-1_012

تاریخ نمایه سازی: 4 مرداد 1402

Abstract:

Power systems are a complex system, which to control them in steady state, different control loops are needed. Load changes affect the frequency of electrical networks. Frequency stabilization (FS) is very important due to the increasing penetration of renewable energy sources in power systems. The main task of load frequency control is to keep the system frequency according to the specified nominal value and to maintain the correct amount of exchange power between the control areas. In this paper, load frequency control (LFC) in single-area power system (SIPS) is studied and simulated. Each area has a steam generating unit with a reheat steam turbine. The system equations are expressed in the state space and the system model is determined based on the transfer function. The simulation results have been obtained using Matlab software. The simulation results show the effect of reheater's parameters on the transient dynamic behavior of the system.

Authors

Mehdi Riahinasab

‎Department of Electrical Engineering, Najafabad Branch, Islamic ‎Azad University, Najafabad, Iran

Neda Behzadfar

Smart Microgrid Research Center, Najafabad Branch, Islamic Azad ‎University, Najafabad, Iran

Homa Movahednejad

‎Department of Computer Engineering, Najafabad Branch, Islamic ‎Azad University, Najafabad, Iran