Exergy Analysis of a Domestic Refrigerator with R134a
Publish place: The 14th Conference of chemical Engineering
Publish Year: 1391
نوع سند: مقاله کنفرانسی
زبان: English
View: 1,612
This Paper With 5 Page And PDF Format Ready To Download
- Certificate
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
NICEC14_098
تاریخ نمایه سازی: 3 آذر 1391
Abstract:
In this study, exergetic analysis of a domestic freezer-refrigerator in one ON-OFF cycle is presented. Relative irreversibility of the components is plotted versus time. The results show that the maximum exergy destruction occurs in the compressor followed by the condenser, capillary tube, freezer evaporator, refrigerator evaporator and superheating coil, respectively. Furthermore, the amount of exergy destruction of all components except the compressor decreases by time. According to the results, compressor improvement highly enhances the cycle
Keywords:
Authors
Mahmood Mastani Joybari
Department of chemical engineering, University of Isfahan
Fatemeh Modarres
Entekhab Industrial Group
مراجع و منابع این Paper:
لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :