Study on the Effects of Combustion Flue Gas Dsicharge from Cracking Furnaces on Camping Area in Firoozabad Petrochemical Plant
Publish place: The 14th Conference of chemical Engineering
Publish Year: 1391
نوع سند: مقاله کنفرانسی
زبان: English
View: 934
This Paper With 5 Page And PDF Format Ready To Download
- Certificate
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
NICEC14_868
تاریخ نمایه سازی: 3 آذر 1391
Abstract:
Discharge of furnaces makes plume which affect on personnel inhalation and around area temperature. This plume shall be strictly studied to specify their effects on personnel and aroundprocess area. Furnaces discharge, often contains COx and NOx components. Beside, temperatureeffects of plume should be checked to assure the lack of effects on the process of around facilities particularly on the exchangers and air coolers. COx & NOx concentration and temperature effectsof discharge gas from 8 furnaces in Firoozabad petrochemical plant are studied in this paper. The gas dispersion modelling using UDM-PHAST is applied in the worst cases to study the effects of furnaces discharge. Results of modelling are also presented and discussed here
Keywords:
Authors
K Karimpour
Chemical Engineering Faculty, University of Tehran, Tehran, Iran
مراجع و منابع این Paper:
لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :