Performance Evaluation of Diagnostic X-Ray Equipment Regarding the Hospital Size in the Republic of Korea

Publish Year: 1398
نوع سند: مقاله ژورنالی
زبان: English
View: 65

This Paper With 5 Page And PDF Format Ready To Download

  • Certificate
  • من نویسنده این مقاله هستم

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این Paper:

شناسه ملی سند علمی:

JR_IJMP-16-3_002

تاریخ نمایه سازی: 5 شهریور 1402

Abstract:

Introduction: The Republic of Korea has developed a national standard based on which diagnostic X-ray equipment must be tested every ۳ years. Accordingly, the performance of X-ray equipment used in all hospitals is evaluated by national certification bodies in compliance with the safety management regulations for X-ray equipment. However, if the equipment is non-compliant, its use must be stopped until it satisfies the accepted standards. Material and Methods: In compliance with the safety management regulations for diagnostic X-ray equipment, hospitals in this study were divided into two groups, namely the general hospital group and the clinic group with diagnostic X-ray equipment. The samples in this study were composed of ۱۱ and ۱۸ machines selected randomly from general hospitals and clinics, respectively, which satisfied the acceptance standards since last year in both groups. The evaluation of diagnostic X-ray machines was based on the results obtained from X-ray tube voltage, tube current, exposure time accuracy, and the X-ray dose reproducibility. Results: The X-ray machines of the general hospital group followed all national standards. However, those of the clinic group failed to satisfy the requirements of tube voltage, tube current, exposure time accuracy, and X-ray dose reproducibility. Conclusion: Clinics require their own quality control to reduce unnecessary medical radiation exposure due to the poor X-ray equipment performance. Moreover, it is suggested that the test period of the safety management regulations on diagnostic X-ray equipment need to be shorter than three years.

Keywords:

Diagnostic Equipment Quality Control Reproducibility , safety management

Authors

Dongjun Jang

Radiological Science, Gachon University Medical Campus, Incheon, Korea

sungchul Kim

Radiological Science, Gachon University Medical Campus, Incheon, Korea

مراجع و منابع این Paper:

لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :