An Investigation on the Anode Distribution in Cathodic Protection by Impressed Current on the Corrosion of Reinforced Concrete
Publish Year: 1399
نوع سند: مقاله ژورنالی
زبان: English
View: 67
This Paper With 14 Page And PDF Format Ready To Download
- Certificate
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_ICAC-9-37_003
تاریخ نمایه سازی: 5 آذر 1402
Abstract:
In this paper, the effect of anode arrangement is investigated on the applied current density in the cathodic protection system of reinforced concrete. For this purpose, two different arrangements of anodes with different number of anodes have been studied. The results indicate that the location of anodes relative to the rods in concrete has a significant effect on the current density. And the amount of applied current density for corrosion protection is a function of the anodes location. In the case where the anodes are parallel to the rods, a lower applied current density is required, and if the anodes are vertical to the rods, a higher current density is required for protection