Exploring the Diagnostic Potential of Infrared Thermography for Experimental Assessment of Cavitation and Air Entrainment-induced Faults in Centrifugal Pumps

Publish Year: 1403
Type: Journal paper
Language: English
View: 144

This Paper With 18 Page And PDF Format Ready To Download

این Paper در بخشهای موضوعی زیر دسته بندی شده است:

Export:

Link to this Paper:

Document National Code:

JR_JAFM-17-2_005

Index date: 9 December 2023

Exploring the Diagnostic Potential of Infrared Thermography for Experimental Assessment of Cavitation and Air Entrainment-induced Faults in Centrifugal Pumps abstract

This research pioneers the application of thermographic principles to diagnose faults, specifically cavitation and air entrainment, in centrifugal pumps. The study represents the inaugural investigation into the feasibility of leveraging infrared thermography for this purpose, underpinned by rigorous experimental methodologies to validate its efficacy. By capturing thermal images of pumps operating under varying conditions, a pseudo-coloring technique for precise temperature range segmentation was employed. This technique facilitated the assessment of fault severity, quantified through the computation of the . This index emerged as a quantifiable metric of fault severity, with elevated values correlating to more pronounced degrees of fault occurrence. Notably, in the case of air entrainment faults, a maximum temperature escalation of 3.9°C was recorded after 60 min run time, and the corresponding thermal index was found to be 5.12. The investigation employs the HSV model, extracting regions of thermal variation through hue differences for fault detection. This process is combined with edge detection methods like Sobel, Prewitt, Roberts, Canny, and Otsu. The Otsu technique consistently outperformed alternative approaches. Specifically, for high cavitation and air entrainment faults, the Otsu method had the highest mean of 0.1730 and 0.1253, respectively. Key findings include the effectiveness of image processing techniques, statistical measures, and edge detection methods for fault diagnosis, as well as insights into temperature differentials and motor load reductions with increasing fault severity. The research improves maintenance, enhancing efficiency and reducing downtime. It emphasizes infrared thermography's potential for fault diagnosis while identifying constraints and advocating further research.

Exploring the Diagnostic Potential of Infrared Thermography for Experimental Assessment of Cavitation and Air Entrainment-induced Faults in Centrifugal Pumps Keywords:

Exploring the Diagnostic Potential of Infrared Thermography for Experimental Assessment of Cavitation and Air Entrainment-induced Faults in Centrifugal Pumps authors

A. K. Goel

SCSQR, Indian Institute of Technology (IIT), Kharagpur, West Bengal, ۷۲۱۳۰۲, India

V. N. A. Naikan

SCSQR, Indian Institute of Technology (IIT), Kharagpur, West Bengal, ۷۲۱۳۰۲, India

مراجع و منابع این Paper:

لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :
Alfayez, L., Mba, D., & Dyson, G. (۲۰۰۵). The application ...
Muhirwa, A., Bisengimana, E., Binama, M., & Muhirwa, A. (۲۰۱۶). ...
Samanipour, P., Poshtan, J., & Sadeghi, H. (۲۰۱۷). Cavitation detection ...
Towsyfyan, H., Gu, F., Ball, A. D., & Liang, B. ...
نمایش کامل مراجع