Introduce a new three-dimensional dosimetry method of IMRT with radiochromic film and comparison results with Monte Carlo simulation and Full Scatter Convolution computational algorithm in the heterogeneous head phantom

Publish Year: 1402
نوع سند: مقاله کنفرانسی
زبان: English
View: 72

نسخه کامل این Paper ارائه نشده است و در دسترس نمی باشد

  • Certificate
  • من نویسنده این مقاله هستم

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این Paper:

شناسه ملی سند علمی:

RSACONG03_029

تاریخ نمایه سازی: 20 آذر 1402

Abstract:

Objective: The main idea of this research is to apply batch of radiochromic films, close to each other in a heterogeneous head phantom to assess the quality assurance of IMRT treatments. Introduced a new method for three-dimensional dosimetry in IMRT technique with the use of a set of radiochromic films in heterogeneous head phantom is the main objective of the current project.Methods: First, the dosimetric characteristics of LinaTech DMLC-H multi leaf collimator using different experimental measurement tools (EDGE detector and EBT۳ film) and Monte Carlo simulations were determined. The Siemens Primus ۶ MV head, together with the external MLC using a VARMLC module in the BEAMnrc code were simulated according to the specifications of their manufacturers. After making anthropomorphic head phantom, PTV and OAR areas, according to RTOG H-۰۰۲۲ protocol were defined within the phantom and then accordance with the provisions of this Protocol, the doses were applied with appropriate restrictions and ultimately IMRT treatment plan using the TiGRT treatment planning system (FSC algorithm) was performed. The phantom was irradiated by substituting batch of the radiochromic films at intervals of ۳ mm and ۱ mm. IMRT treatment plan in a heterogeneous environment was simulated by EGSnrc code. The results of the three-dimensional dose distribution obtained from FSC algorithm and MC calculations were compared with the measured dose distribution and were analyzed using conventional criteria (۳ mm-۳%) by γ index.Results: The good agreement was observed between experimental measurements and simulated MLC. The results showed that the dosimetric characteristics of DMLC-H are consistent with the criteria specified in international standards. Dose distributions obtained from the anthropomorphic head phantom showed that in axial, coronal, and sagittal planes, by improving the resolution (۳ to ۱ mm) γ pass rate of FSC algorithm and MC calculations respectively about ۳% and ۱.۵% increase. Also, in these planes, the differences in the γ pass rate between the FSC algorithm and MC simulation with a resolution of ۳ mm and ۱ mm are about ۸.۵% and ۷.۴%, respectively. In general, the acceptance rate of γ index calculated by the FSC algorithm and MC simulation was obtained in the range of ۸۹%-۹۲% and ۹۸%-۹۹%, respectively.Conclusion: The results of this study show that the ۳D gamma passing rate obtained from the FSC algorithm in the heterogeneous head phantom is less than expected and desirable value (≥۹۵%), while Monte Carlo calculations showed excellent agreement with experimental results

Authors

Mikaeil Molazadeh

Department of Medical Physics, Faculty of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran

Alireza Shirazi

Department of Medical Physics and Biomedical Engineering, Faculty of Medicine, Tehran University of Medical Sciences, Tehran, Iran

Ghazale Geraily

Department of Medical Physics and Biomedical Engineering, Faculty of Medicine, Tehran University of Medical Sciences, Tehran, Iran

Ahahd Zeinali

Department of Medical Physics, Faculty of Medicine, Urmia University of Medical Sciences, Urmia, Iran