Evaluation of deformable image registration in HDR gynecological brachytherapy
Publish place: Iranian Journal of Medical Physics، Vol: 15، Issue: 0
Publish Year: 1397
نوع سند: مقاله ژورنالی
زبان: English
View: 89
نسخه کامل این Paper ارائه نشده است و در دسترس نمی باشد
- Certificate
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_IJMP-15-0_221
تاریخ نمایه سازی: 29 آذر 1402
Abstract:
Introduction: In brachytherapy, as in external radiotherapy, image-guidance plays an important role. For GYN treatments it is standard to acquire at least CT images and preferably MR images prior to each treatment and to calculate the dose of the day on each set of images. Then, the dose to the target and to the organs at risk (OAR) is calculated with worst case scenario from ICRU recommendation that propose add maximum doses to the volume of ۲cc of every organ (D۲cc) from every session. Especially for the OAR, it makes the safe conservative assumption that the same part of the OAR always receives the highest dose. The dose calculated this way often limits the prescription dose or the target coverage. In this work, we propose to investigate an alternative method to assess the cumulative dose for an HDR GYN treatment course; the use of image deformation software to track the deformations of the OAR from one fraction to the next. Materials and Methods: Thirty patients with locally advanced cervical cancer who had been treated by external beam radiotherapy (EBRT) and three to four fractions of HDR brachytherapy (HDR-BT) were introduced to this study. Intensity-based free form deformation algorithm has been used as the primary DIR techniques using MIM software. In the dose accumulationn stage, total doses of rectum and bladder from all brachytherapy fractions have been integrated by deformable image registration techniques. Results: The DICE, jaccard, MDA and HD indexes of deformable registration for bladder and rectum were (۰.۹۴±۰.۰۳), (۰.۸۹±۰.۰۶), (۰.۸۳±۰.۳), (۹.۸۵±۳.۸) and (۰.۸۶±۰.۰۵), (۰.۷۸±۰.۰۷), (۱.۴۶±۰.۷), (۱۴.۴±۰.۱) respectively compared to rigid registration for bladder and rectum that were (۰.۷۴±۰.۰۷), (۰.۶۱±۰.۰۷), (۴.۲±۲.۳), (۱۸.۷۳±۸.۶) and (۰.۵۹±۰.۱۳), (۰.۴۳±۰.۱۱), (۵.۰۱±۱.۷), (۲۳.۴±۱.۱) respectively. Dose accumulation of D۲cc values were (۵.۱±۲,۳)% and (۲.۷±۱.۱)% lower for the bladder and rectum respectively compared to adding D۲cc of each fractions. Conclusion: Using deformable image registration, based on image intensity, allows to accumulate the dose from different brachytherapy fractions. The results from our study indicate that it is feasible to utilize deformable image registration for dose accumulation.
Keywords:
Authors
Reza Mohammadi
Department of Medical Physics, Iran University of Medical Sciences, Tehran, Iran Medical Image and Signal Processing Research Core, Iran University of Medical Sciences, Tehran, Iran
Ramin Jaberi
Department of Radiotherapy, Cancer Institute, Tehran University of Medical Science, Tehran, Iran
Reza Reiazi
Department of Medical Physics, Iran University of Medical Sciences, Tehran, Iran Medical Image and Signal Processing Research Core, Iran University of Medical Sciences, Tehran, Iran
Seyed Rabee Mahdavi
Department of Medical Physics, Iran University of Medical Sciences, Tehran, Iran