Design and Implementation of a Monte Carlo Framework for Assessment of Spoiler Applications in Abutting Electron Fields
Publish Year: 1399
نوع سند: مقاله ژورنالی
زبان: English
View: 241
This Paper With 8 Page And PDF Format Ready To Download
- Certificate
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_JBPE-10-3_011
تاریخ نمایه سازی: 30 دی 1402
Abstract:
Background: Field matching problems in abutting electron fields can be managed by using spoilers.Objective: The aim of this study was to design a Monte Carlo framework for the assessment of spoiler application in abutting electron fields.Material and Methods: In this experimental study, a Siemens Primus treatment head was simulated for a ۵ MeV electron beam using BEAMnrc, DOSXYZnrc and EGSnrc user codes. Validation of beam model was done by measurement using a MP۳-M water tank and a Semi-flex Chamber-۳۱۰۱۰ (PTW, Freiburg, Germany). An in-house routine was developed to calculate the combined isodose curves resulting from simulated adjacent fields. The developed framework was analyzed using PMMA and chromium spoilers. Results: The penumbra width increased from ۲۷.۵ mm for open fields to ۴۲ mm for PMMA and ۴۰ mm for chromium. The maximum junction dose reduced from ۱۱۵% for open fields to ۱۰۷% for PMMA and ۱۰۸% for chromium. R۹۰ reduced about ۶ mm for PMMA and ۳ mm for chromium. Uniformity index reduced from ۹۳% to ۷۷% for both spoilers. Surface dose increased from ۷۹% to ۸۹% for PMMA and ۸۸% for chromium. Conclusion: Using spoilers, penumbra width at the surface was increased, size and depth of hot spots as well as the therapeutic range were reduced and dose homogeneity at the junction of abutting electron fields was improved. For both spoilers, the uniformity index reduced, and surface percent dose increased. The results of this research can be used to optimize dose distribution in electron beam treatment using abutting fields.
Keywords:
Authors
F Felfeliyan
MSc, Department of Medical Physics, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
M Atarod
PhD, Department of Medical Physics and Radiology, Shahrekord University of Medical Sciences, Shahrekord, Iran
A Amouheidari
MD, Department of Radiation Oncology, Milad Hospital, Isfahan, Iran
S Noshadi
MSc, Department of Medical Physics, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
P Shokrani
PhD, Department of Medical Physics, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
مراجع و منابع این Paper:
لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :