A Novel Study in the Determination of Loratadine in Pharmaceutical Samples by Precipitating with ۳,۵-Dinitrosalicylic Acid Utilizing the NAG_۴SX۳_۳D Analyzer at ۰-۱۸۰o in Conjunction with the Continuous Flow Injection Analysis (CFIA) Technique

Publish Year: 1403
نوع سند: مقاله ژورنالی
زبان: English
View: 42

This Paper With 18 Page And PDF Format Ready To Download

  • Certificate
  • من نویسنده این مقاله هستم

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این Paper:

شناسه ملی سند علمی:

JR_AJCS-7-3_003

تاریخ نمایه سازی: 24 بهمن 1402

Abstract:

An innovative and effective method for continuous flow injection analysis (CFIA) was developed and included in the NAG_۴SX۳_۳D Analyzer. The primary objective of this approach was to quantify the concentration of loratadine. This study presents a methodology for the quantification of loratadine, an antihistaminic medication, in pharmaceutical formulations. The samples are analyzed using the NAG_۴SX۳_۳D Analyzer, which is a device that combines optical, chemical, electronic, and detection capabilities. The analyzer operates by receiving a cumulative signal, eliminating the need for amplification. The total distance travelled is ۷۶۰ mm in relation to the variable YZ -mV during a period of time represented by t seconds (measured in mm). The selection was made based on the accurate computation of the energy transducer profile. The relative standard deviations for loratadine are ۰.۰۹% at a concentration of ۵ m.M and ۰.۱% at a concentration of ۸ m.M for n = ۶. The limit of detection (LOD) and limit of quantification were found to be ۶۱۱.۰۷۶ ng and ۱۲۹ μg, respectively, using a stepwise dilution of the lowest concentration on the calibration curve with a sample size of n = ۱۳. The linear range has a correlation coefficient (r) of ۰.۹۹۸۹, indicating a strong positive relationship. Additionally, the linearity of this range is measured at ۹۹.۷۹% (R۲) and recovery is not less than ۹۶.۵۸%, suggesting a high degree of conformity to a linear model. A comparative analysis was conducted between the outcomes of the suggested methodology and the existing UV-spectrophotometric approach, specifically at a wavelength of ۲۷۵nm, revealing similar findings.

Keywords:

Loratadine , Continuous flow Injection analysis (CFIA) , NAG-۴SX۳-۳D analyzer

Authors

Issam Mohammad Shakir

College of Science, Chemistry Department, University of Baghdad, Republic of Iraq

Bakr Sadiq Mohammed

College of Science, Chemistry Department, University of Baghdad, Republic of Iraq

Nagham Shakir Turkey

College of Science, Chemistry Department, University of Baghdad, Republic of Iraq

مراجع و منابع این Paper:

لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :