Analysis of the behavior of reinforced concrete buildings with and without non-buckling braces under the effect of earthquake loads

Publish Year: 1402
نوع سند: مقاله ژورنالی
زبان: English
View: 41

This Paper With 7 Page And PDF Format Ready To Download

  • Certificate
  • من نویسنده این مقاله هستم

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این Paper:

شناسه ملی سند علمی:

JR_JCER-5-3_004

تاریخ نمایه سازی: 27 بهمن 1402

Abstract:

The moment frame is one of the most widely used seismic resistant systems in the world, due to its high formability and flexibility, this system causes a lot of displacement in the structure and force exceeding the capacity of the structural components. The bracing system is a suitable method to control the lateral displacement of the structure and the seismic improvement of the bending frame. The new type of bracing system that is used in the design of new systems and the improvement of old structures is non-buckling bracing, and in this research, their effect on the performance of ۴, ۷, and ۱۰-story concrete moment frames under the Northridge, San Salvador, and Tabas earthquake has been investigated. The research method in this research is analytical-applied, which the results of this study showed; In the ۴-story structure, the amount of wasted energy under the ۳ considered earthquakes is equal to ۰%, ۰%, and ۱% without buckling braces and ۳۹%, ۴۸% and ۵۰% in the case with non-buckling braces and in the ۷- story structure, the amount of energy consumed under the mentioned ۳ earthquakes is equal to ۰%, ۰% and ۰% without buckling braces and ۴۰%, ۴۵% and ۵۱% in the case with non-buckling braces and also in the ۱۰- story structure, the amount of energy consumed under the above ۳ earthquakes is equal to ۱%, ۰% and ۱۱% without buckling braces and ۳۵%, ۴۲% and ۴۵% in the case with non-buckling braces. So, it was concluded that the performance of the structure in the case with non-buckling braces is better than in the case without non-buckling braces.The moment frame is one of the most widely used seismic resistant systems in the world, due to its high formability and flexibility, this system causes a lot of displacement in the structure and force exceeding the capacity of the structural components. The bracing system is a suitable method to control the lateral displacement of the structure and the seismic improvement of the bending frame. The new type of bracing system that is used in the design of new systems and the improvement of old structures is non-buckling bracing, and in this research, their effect on the performance of ۴, ۷, and ۱۰-story concrete moment frames under the Northridge, San Salvador, and Tabas earthquake has been investigated. The research method in this research is analytical-applied, which the results of this study showed; In the ۴-story structure, the amount of wasted energy under the ۳ considered earthquakes is equal to ۰%, ۰%, and ۱% without buckling braces and ۳۹%, ۴۸% and ۵۰% in the case with non-buckling braces and in the ۷- story structure, the amount of energy consumed under the mentioned ۳ earthquakes is equal to ۰%, ۰% and ۰% without buckling braces and ۴۰%, ۴۵% and ۵۱% in the case with non-buckling braces and also in the ۱۰- story structure, the amount of energy consumed under the above ۳ earthquakes is equal to ۱%, ۰% and ۱۱% without buckling braces and ۳۵%, ۴۲% and ۴۵% in the case with non-buckling braces. So, it was concluded that the performance of the structure in the case with non-buckling braces is better than in the case without non-buckling braces.

Authors

Alireza Sheikhnasiri

Ph.D Student, Structural Orientation, Faculty of Islamic Azad University, (Chalous Branch), Mazandaran, Chalous, Iran