سیویلیکا را در شبکه های اجتماعی دنبال نمایید.

Lag screw principle to fix unstable sagittal fracture of infraorbital rim: A technical note

Publish Year: 1402
Type: Journal paper
Language: English
View: 70

متن کامل این Paper منتشر نشده است و فقط به صورت چکیده یا چکیده مبسوط در پایگاه موجود می باشد.
توضیح: معمولا کلیه مقالاتی که کمتر از ۵ صفحه باشند در پایگاه سیویلیکا اصل Paper (فول تکست) محسوب نمی شوند و فقط کاربران عضو بدون کسر اعتبار می توانند فایل آنها را دانلود نمایند.

Export:

Link to this Paper:

Document National Code:

JR_JEPT-9-1_011

Index date: 2 August 2024

Lag screw principle to fix unstable sagittal fracture of infraorbital rim: A technical note abstract

Objective: Fractures of orbital rims are common and restoration of these fractures back toits normal anatomic form is essential to maintain the function and aesthetics of the eyes.Low profile miniplates are the rigid fixation device of choice for such fractures. But in caseof sagittal and grossly displaced fractures of orbital rims it is difficult to achieve stability byusing miniplate osteosynthesis. The low profile miniplates may not be able to withstandthe forces to reduce this kind if grossly displaced fractures, another stable option needs tobe considered in these situations.Case presentation: This case report presents a simple and effective technique of reductionand fixation of an oblique fracture of infraorbital rim fracture using lag screw principle.A standard titanium screw of 2 mm diameter and 10 mm length is being used in thedescribed technique for stable fixation of fractured segments.Conclusion: The technique is simple, hardware’s are easily available and can be practisedin emergency circumstances where newer advanced technologies are not available

Lag screw principle to fix unstable sagittal fracture of infraorbital rim: A technical note Keywords:

Lag screw principle to fix unstable sagittal fracture of infraorbital rim: A technical note authors

Smita Bhat

Department of Oral and Maxillofacial Surgery, SDM College of Dental Sciences and Hospital, A Constituent College of Shri Dharmasthala Manjunatheshwara University, Dharwad, Karnataka, India

Amal Suresh

Department of Oral and Maxillofacial Surgery, SDM College of Dental Sciences and Hospital, A Constituent College of Shri Dharmasthala Manjunatheshwara University, Dharwad, Karnataka, India

Apeksha Inamdar

Department of Oral and Maxillofacial Surgery, SDM College of Dental Sciences and Hospital, A Constituent College of Shri Dharmasthala Manjunatheshwara University, Dharwad, Karnataka, India

Anil Kumar Desai

Department of Oral and Maxillofacial Surgery, SDM College of Dental Sciences and Hospital, A Constituent College of Shri Dharmasthala Manjunatheshwara University, Dharwad, Karnataka, India

Gopal Krishnan

Department of Oral and Maxillofacial Surgery, SDM College of Dental Sciences and Hospital, A Constituent College of Shri Dharmasthala Manjunatheshwara University, Dharwad, Karnataka, India

مراجع و منابع این Paper:

لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :
Darwich A, Attieh A, Khalil A, Szávai S, Nazha H. ...
Crespo Reinoso P, Jerez Robalino J, de Santiago MG. Biomechanics ...
Ramasubbu S. Lag screws in maxillofacial trauma-a review. J Pharm ...
Kotrashetti SM, Singh AG. Prospective study of treatment outcomes with ...
نمایش کامل مراجع