A New Relationship for Determining the Impact Force between Two Adjacent Structures Considering Building Pounding

Publish Year: 1401
Type: Journal paper
Language: English
View: 75

This Paper With 15 Page And PDF Format Ready To Download

Export:

Link to this Paper:

Document National Code:

JR_CIVLJ-10-1_009

Index date: 12 September 2024

A New Relationship for Determining the Impact Force between Two Adjacent Structures Considering Building Pounding abstract

Insufficient separation distance between two adjacent buildings can cause to collision when large lateral displacements are accrued due to seismic excitation. The impact force between structures induces many serious damages, which is called building pounding. In this study, pounding between two dynamic models is investigated and the impact force is numerically calculated. The impact is simulated based on special elements, including spring and dashpot, and the impact force and dissipated energy during the impact are determined. Both mentioned parameters depend significantly on the impact velocity, spring stiffness and the value of damping. For this purpose, the impact velocity of collision is parametrically measured and subsequently, coefficient of restitution is automatically determined. Furthermore, the impact damping ratio and nonlinear stiffness of spring are calculated to evaluate the impact between models. Finally, a new equation is presented to determine the value of damping and the accuracy of formula is confirmed, which is verified by three various approaches. In the first stage, an experimental test is considered and the peak impact force is extracted when a concrete ball is dropped on a rigid concrete surface. On the other hand, a numerical simulation is similarly assumed and the suggested formula is used to determine the peak impact force during collision. Then, the results of the peak impact forces between experimentally and numerically analyses are compared, which shows both are close to each other. Secondly, an estimated impact between two bodies has been studied. The results of the analysis are also compared between the dissipated and kinetic energies during impact. The comparisons indicate relatively low errors between the calculated and assumed values of the coefficient of restitution when the proposed equation is used. Finally, a value of the coefficient of restitution is selected and an impact is simulated to show hysteresis loop. The enclosed area of each loop is calculated as the dissipated energy and compared with the energy absorption. The above three comparisons show that the proposed formula is very effective and the accuracy of the impact force, calculated by the suggested formula as a parameter of the impact force model, is also acceptable.

A New Relationship for Determining the Impact Force between Two Adjacent Structures Considering Building Pounding Keywords:

A New Relationship for Determining the Impact Force between Two Adjacent Structures Considering Building Pounding authors

Yaghub Ebrahimi

Ph.D. Candidate, Civil Engineering Department, Semnan Branch, Islamic Azad University, Semnan, Iran

Alireza Mortezaei

Associate Professor, Seismic Geotechnical and High Performance Concrete Research Centre, Civil Engineering Department, Semnan Branch, Islamic Azad University, Semnan, Iran

Ali Hemmati

Assistant Professor, Seismic Geotechnical and High Performance Concrete Research Centre, Civil Engineering Department, Semnan Branch, Islamic Azad University, Semnan, Iran

Mahmoud Nikkhah Shahmirzadi

Assistant Professor, Seismic Geotechnical and High Performance Concrete Research Centre, Civil Engineering Department, Semnan Branch, Islamic Azad University, Semnan, Iran

مراجع و منابع این Paper:

لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :
Papadrakakis M, Mouzakis HP. Earthquake simulator testing of pounding between ...
Filiatrault A, Wagner P, Cherry S. Analytical prediction of experimental ...
Papadrakakis M, Mouzakis H, Plevris N, Bitzarakis S. A lagrange ...
Shakya K, Wijeyewickrema AC. Mid-Column Pounding of Multi-Story Reinforced Concrete ...
Kajita Y, Kitahara T, Nishimoto Y, Otsuka H. Estimation of ...
Jankowski R, Mahmoud S. Linking of adjacent three-storey buildings for ...
Masroor A, Mosqueda G. Experimental simulation of base-isolated buildings pounding ...
Jankowski R. Pounding Between Superstructure Segments in Multi-Supported Elevated Bridge ...
Crozet V, Politopoulos I, Chaudat T. Shake table tests of ...
Anagnostopoulos SA. Pounding of buildings in series during earthquakes. Earthq ...
Anagnostopoulos SA. Equivalent viscous damping for modeling inelastic impacts in ...
Miari M, Choong KK, Jankowski R. Seismic pounding between adjacent ...
Jankowski R. Non-linear viscoelastic modelling of earthquake-induced structural pounding. Earthq ...
Komodromos P, Polycarpou PC, Papaloizou L, Phocas MC. Response of ...
Komodromos P, Polycarpou P. On the numerical simulation of impact ...
Ye K, Li L, Zhu H. A note on the ...
Kun C, Yang Z, Chouw N. Seismic response of skewed ...
Barros RC, Naderpour H, Khatami SM, Mortezaei A. Influence of ...
Naderpour H, Barros RC, Khatami SM. A new model for ...
Mahmoud S, Chen X, Jankowski R. Structural Pounding Models with ...
Mahmoud S, Jankowski R. Modified linear viscoelastic model of earthquake-induced ...
Naderpour H, Barros RC, Khatami SM, Jankowski R. Numerical Study ...
Naderpour H, Khatami SM, Barros RC. Prediction of critical distance ...
Khatami SM, Naderpour H, Barros RC, Jakubczyk-Gałczyńska A, Jankowski R. ...
Xu X, Xu X, Liu W, Zhou D. A New ...
Mortezaei A, Ronagh HR. Effectiveness of modified pushover analysis procedure ...
Mortezaei A. Plastic hinge length of RC columns considering soil-structure ...
نمایش کامل مراجع