Abstract:
Earthquakes have been a major source of destruction in the developed as well as under developed nations, particularly damaging the Un-Reinforced Masonry construction in the ‘In-Plane’ and ‘Out-of-Plane’ bending behaviour. The various retrofitting techniques such as the Fibre-Reinforced Polymer Reinforcement, Post tensioning using rubber tyres etc are uneconomical to be put into practice. This paper presents a case study on the seismic evaluation and retrofit design for the Institute of Blind, sector 26, Chandigarh, a building of considerable importance. This building is a lifeline structure and would serve as an added reserve for rehabilitation work during any catastrophe. Seismic evaluation of this masonry building has been carried out using Simplified Equivalent static analysis. In this method, an analogy has been applied to synchronize the pattern of piers to the springs connected in ‘series’ and ‘parallel’. The design seismic forces have been calculated using the provisions of IS: 1893-2002 for seismic zone IV. The stresses evaluated have been checked for permissible value under various load combinations in accordance with Indian Standard Codes. We plan to provide a safeguard scheme without replacing the existing structure using galvanized welded wire mesh and micro concrete. The mesh reinforcement is provided on both faces of the walls. This method has the smallest thickness as compared to the rest of the retrofit schemes. The cost of retrofit has also been calculated in terms of per square meter area of the building. This retrofitting technique does not require heavy machineries, special material and costly equipments, hence is easier in its implementation compared to other techniques available
Keywords:
Authors
Manik Jain
Student, PEC University of Technolgy
Piyush Bharti Arora
Student, PEC University of Technology
مراجع و منابع این Paper:
لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :