Design and Developed Novel and Ultrasensitive Chemosensor for Sequential Determination of Arginine and Glutathione Amino Acids

Publish Year: 1402
Type: Journal paper
Language: English
View: 84

This Paper With 18 Page And PDF Format Ready To Download

Export:

Link to this Paper:

Document National Code:

JR_IJAC-10-2_008

Index date: 18 November 2024

Design and Developed Novel and Ultrasensitive Chemosensor for Sequential Determination of Arginine and Glutathione Amino Acids abstract

In this study, a novel mixed ligand (Dithizone-Co(II)-Alizarin red S: DTZ-Co-ALR-) ensemble is designed and developed ultra-sensitive, and highly selective to UV-Vis absorption and for naked-eye detection of Arginine (Arg), and Glutathione (GSH). The out coming high sensitivity and selectivity for new receptor (DTZ-Co(II)-ALRs-Arg) was attained by adding Glutathione. The indicator is released due to its displacement from the mixed ligand (DTZ-Co-ALRs-Arg) by Glutathione and the change in absorbance may be due to the further complexation of GSH with the additional coordination sites present in the Arg bonded with the mixed ligand (DTZ-Co-ALRs). The label-free DTZ-Co-ALRs receptor provided sensitive and selective detection of L-Arginine, and Glutathione with detection limits of 0.03, and 0.009µmol L-1, respectively. The protocol especially offers high selectivity for the determination of Arg, and GSH among amino acids found in real samples. Moreover, the investigation of the logic behavior of the proposed DTZ-Co-ALRs receptor indicated its capability of functioning as an INHIBIT-type colorimetric chemosensor with the chemical inputs and UV-Vis absorbance signal as the output. This mixed ligand receptor could also behave as a molecular “keypad lock” with the correct sequential addition of Arg and GSH inputs.

Design and Developed Novel and Ultrasensitive Chemosensor for Sequential Determination of Arginine and Glutathione Amino Acids Keywords:

Design and Developed Novel and Ultrasensitive Chemosensor for Sequential Determination of Arginine and Glutathione Amino Acids authors

Hossein Tavalali

Department of Chemistry, Payame Noor University ۱۹۳۹۵-۴۶۹۷ Tehran, Iran

Abolfath Parhami

Department of Chemistry, Payame Noor University ۱۹۳۹۵-۴۶۹۷ Tehran, Iran

Mohammad Ali Karimi

Department of Chemistry, Payame Noor University ۱۹۳۹۵-۴۶۹۷ Tehran, Iran

Jamshid Askari

Department of Chemistry, Payame Noor University ۱۹۳۹۵-۴۶۹۷ Tehran, Iran