Corrosion Detection in Pipe Elbow Using Ultrasonic Guided Waves
Publish Year: 1390
Type: Conference paper
Language: English
View: 1,185
This Paper With 5 Page And PDF Format Ready To Download
- Certificate
- I'm the author of the paper
Export:
Document National Code:
ICME12_337
Index date: 16 September 2013
Corrosion Detection in Pipe Elbow Using Ultrasonic Guided Waves abstract
Corrosion in fuel and gas pipelines is a critical issue since it can cause leakage of fuel and sometimes explosion which leads to catastrophic disaster. Therefore non-destructive test of these structures for detecting defects particularly wall thinning is of vital importance. In whole testing of pipelines, elbow region needs more attention because of the existence of residual stresses and also turbulence flaw of fluid that both aggravate the corrosion and finally failure. During the past decade, utilizing ultrasonic guided waves for flaw detection in pipelines has drawn a lot of attention but the use of guided waves in pipe elbow region needs more research to be a more practical method. In this paper, the application of ultrasonic guided waves for detecting corrosion in pipe elbow region was experimentally investigated. Three 20 mm width notches with different depth- 30%, 50% and 70 % pipe wall thickness were milled on 6 inch pipe elbow as artificial corrosion defects. These defects were successfully detected via longitudinal mode of ultrasonic guided waves.
Corrosion Detection in Pipe Elbow Using Ultrasonic Guided Waves Keywords:
Corrosion Detection in Pipe Elbow Using Ultrasonic Guided Waves authors
J. Rostami
Depertment of mechanical and Aerospace Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran
M.S. Safizadeh
School of Mechanical Engineering, Iran University of Science and Technology, Tehran, Iran
مراجع و منابع این Paper:
لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :