سیویلیکا را در شبکه های اجتماعی دنبال نمایید.

Comparison of cold and tepid modified delnido cardioplegia on myocardial protection in open heart surgery patients

Publish Year: 1403
Type: Journal paper
Language: English
View: 59

This Paper With 10 Page And PDF Format Ready To Download

Export:

Link to this Paper:

Document National Code:

JR_CBJ-4-2_002

Index date: 25 February 2025

Comparison of cold and tepid modified delnido cardioplegia on myocardial protection in open heart surgery patients abstract

Objectives: Cardioplegia is a crucial component of myocardial protection during aortic cross-clamping and cardiopulmonary bypass. It has been reported to provide effective myocardial protection and improved clinical outcomes with enhanced surgical flow in adult cardiac procedures. This study investigates the efficacy and safety of cold-modified Del Nido cardioplegia versus tepid blood cardioplegia in adult cardiac surgery patients using Myotherm, a device mainly used in cardiac surgery to monitor and manage the myocardial temperature during surgery.Methods: After obtaining approval from the ethics committee and establishing entry criteria that included age, type of heart surgery, and absence of cardioplegic contraindications, the researchers defined exclusion criteria-  such as previous heart surgery or significant comorbidities. Seventy patients were randomly divided into two groups: Group A received a cold solution at  4°C ( n=35), while Group B received a tepid solution at 28°C (n=35). The amount of cardioplegia was 10 to 15 cc/kg and was injected with a pressure of 70 to 90 mm Hg in an anterograde manner. The temperature of cardioplegia was also adjusted with a Myotherm device. The day before the surgery, a written consent form was obtained from the patients, and the patients were informed about the study method. The sampling method is a double-blind clinical trial to achieve minimal bias, ensuring the reliability of the results and reducing influences on it. This study was conducted in Afshar Hospital in Yazd during 2023 and 2024.Results: There were no significant differences between the two groups in terms of the need for an intra-aortic balloon pump (p=1.0), intraoperative and postoperative inotropic support  (p=0.26), and postoperative pacemaker(p=0.49). Also, there were no significant differences between the two groups in terms of troponin I level after surgery (p=0.50), left ventricular ejection fraction after discharge (p=0.34), time to return of spontaneous heart rhythm (P=0.25), cross-clamp time(P=0.30), cardiopulmonary bypass time (P=0.07), and length of stay in the ICU (P=0.21).Conclusions: The result showed that both techniques provide similar results. Although the time of cross-clamp and cardiopulmonary bypass was shorter in the group using tepid solution, these differences were not statistically significant. In other words, cold and tepid solutions are equally effective and safe to protect the myocardium, and doctors can use both types of solutions during open heart surgery.

Comparison of cold and tepid modified delnido cardioplegia on myocardial protection in open heart surgery patients Keywords:

Myocardial protection , CPB , Cold and Tepid Modified Del Nido cardioplegia , Myotherm

Comparison of cold and tepid modified delnido cardioplegia on myocardial protection in open heart surgery patients authors

Saeed Rostamani

Department of Cardiovascular Research Center, School of Medicine, University of Medical Sciences, Yazd, Iran

Mehdi Hadadzadeh

Yazd Cardiovascular Research Center, Non- communicable Diseases Research Institute, Shahid Sadoughi University of Medical Sciences, Yazd, Iran

Seyed Hossein Moshtaghion

Yazd Cardiovascular Research Center, Non- communicable Diseases Research Institute, Shahid Sadoughi University of Medical Sciences, Yazd, Iran

Farimah Shamsi

Biostatistics center for healthcare data modeling, Shahid Sadoughi university of medical sciences, Yazd, Iran

Ahmad Tajamolian

Yazd Cardiovascular Research Center, Non- communicable Diseases Research Institute, Shahid Sadoughi University of Medical Sciences, Yazd, Iran

مراجع و منابع این Paper:

لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :
Matte GS, del Nido PJ. History and use of del ...
Nakao M, Morita K, Shinohara G, et al. Excellent restoration ...
Ad N, Holmes SD, Massimiano PS, et al. The use ...
Sanetra K, Gerber W, Shrestha R, et al. The del ...
Lenoir M, Bouhout I, Jelassi A, et al. Del Nido ...
Kavala AA, Turkyilmaz S. Comparison of del Nido cardioplegia with ...
Pragliola C, Hassan E, Ismail H, et al. del Nido ...
Yammine M, Neely RC, Loberman D, et al. The use ...
James TM, Stamou SC, Faber C, et al. Whole Blood ...
Stamou SC, Lopez C, Novello C, et al. Modified whole ...
Kantathut N, Cherntanomwong P, Khajarern S, et al. Lactated ringer's ...
Gallo M, Trivedi JR, Slaughter MS. Myocardial protection with complementary ...
Vinten-Johansen J. Whole blood cardioplegia: do we still need to ...
Yamamoto H, Yamamoto F. Myocardial protection in cardiac surgery: a ...
Minatoya K, Okabayashi H, Shimada I, et al. Intermittent antegrade ...
Ghazy T, Allham O, Ouda A, et al. Is repeated ...
Allham O, Ghazy T, Ouda A, et al. Intermittent antegrade ...
Hayashida N, Ikonomidis JS, Weisel RD, et al.The optimal cardioplegic ...
Ramani J, Malhotra A, Wadhwa V, et al. Single-dose lignocaine-based ...
Rao P, Keenan JB, Rajab TK, et al. Intraoperative thermographic ...
Momin AA, Chemtob RA, Lopez DC, et al. Open sternum, ...
Boldt J, Kling D, Dapper F, et al. Myocardial temperature ...
Daily PO, Jones B, Folkerth TL, et al. Comparison of ...
Okamoto H, Tamenishi A, Nishi T, et al. Analysis of ...
نمایش کامل مراجع