سیویلیکا را در شبکه های اجتماعی دنبال نمایید.

Influence of Normal Tissue Objective Tools on Treatment Planning System in Nasopharyngeal Carcinoma (NPC): A 3D Printed Anthropomorphic Phantom Study

Publish Year: 1403
Type: Journal paper
Language: English
View: 35

This Paper With 9 Page And PDF Format Ready To Download

Export:

Link to this Paper:

Document National Code:

JR_IJMP-21-6_008

Index date: 16 March 2025

Influence of Normal Tissue Objective Tools on Treatment Planning System in Nasopharyngeal Carcinoma (NPC): A 3D Printed Anthropomorphic Phantom Study abstract

Introduction: The normal tissue objective (NTO), one of the new aspects in the radiation treatment planning system (TPS), aims to lower the absorbed dose received by organs at risk (OARs) close to the target volume or Planning Target Volume (PTV). This study was conducted to ascertain the impact of planning in nasopharyngeal cancer (NPC) cases both with and without manual NTO settings.Material and Methods: The study used a 3D printed head and neck phantom exposed to radiation using the Intensity Modulated Radiation Therapy (IMRT) technique with 6000 cGy prescribed dose and divided into 30 fractions to find the discrepancies between the manually calculated absorbed dose­ and the automatic calculated absorbed dose of TPS. Moreover, evaluation parameter indicators, including the homogeneity index (HI), conformity index (CI), gradient index (GI), and comprehensive quality index (CQI), were used to make comparisons. NTO parameter used in manual plans are f0 = 107%, f∞ = 65%, dose fall-off  = 0.05 mm-1, and xstart = 0.75 cm.Results: The statistical analysis resulted in a significant difference between the calculated absorbed dose and TPS's absorbed dose of Automatic NTO and Manual NTO, whereas, Without NTO plans, there was no statistical difference. The HI values for Automatic NTO, Manual NTO, and Without NTO are 0.118, 0.05 , and 0.053, respectively. The CI values for Automatic NTO, Manual NTO, and Without NTO are 0.91, 0.99, and 0,19. The GI value for Automatic NTO, Manual NTO, and Without NTO are 3.34, 4.94, and 7.29, respectively. CQI parameter showed that the Automatic NTO plan performs better than the Manual NTO plan based on the maximum dose received by the OAR.Conclusion: In this study, the manual NTO plan showed better performance by reducing hot spots in the central region of PTV.

Influence of Normal Tissue Objective Tools on Treatment Planning System in Nasopharyngeal Carcinoma (NPC): A 3D Printed Anthropomorphic Phantom Study Keywords:

Influence of Normal Tissue Objective Tools on Treatment Planning System in Nasopharyngeal Carcinoma (NPC): A 3D Printed Anthropomorphic Phantom Study authors

Ivory Noersjafrudin

Department of Physics, Institut Teknologi Sepuluh Nopember, Kampus ITS Sukolilo, Surabaya ۶۰۱۱۱, East Java, Indonesia

Ulfi Hanum

Department of Physics, Institut Teknologi Sepuluh Nopember, Kampus ITS Sukolilo, Surabaya ۶۰۱۱۱, East Java, Indonesia

Asmaul Marufah

Department of Physics, Institut Teknologi Sepuluh Nopember, Kampus ITS Sukolilo, Surabaya ۶۰۱۱۱, East Java, Indonesia

Aloysius Putranto

Department of Radiation Oncology, Mochtar Riady Comprehensive Cancer Center (MRCCC) Siloam Hospital Semanggi, Jakarta, ۱۲۹۳۰, Indonesia

Endarko Endarko

Department of Physics, Institut Teknologi Sepuluh Nopember, Kampus ITS Sukolilo – Surabaya ۶۰۱۱۱, East Java, Indonesia

مراجع و منابع این Paper:

لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :
Shreya Sinha, Ajeet Gajra. Nasopharyngeal Cancer [Internet]. Vol. StatPearls[Internet], StatPearls ...
León Marroquin EY, Herrera González JA, Camacho López MA, Villarreal ...
Bolt M, Clark CH, Nisbet A, Chen T. Quantification of ...
نمایش کامل مراجع