Thermodynamic Modeling and Exergy analysis of Gas Turbine Plant ( Case study in Iran)
Publish place: 16th Annual Conference on Mechanical Engineering
Publish Year: 1387
نوع سند: مقاله کنفرانسی
زبان: English
View: 2,352
This Paper With 7 Page And PDF Format Ready To Download
- Certificate
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
ISME16_744
تاریخ نمایه سازی: 20 آبان 1386
Abstract:
Due to the importance of increasing power plants performance in Iran Exergy analysis is a common way for these cycles, Thus For this analysis first each part of gas Turbine Plant were modeled by thermodynamic approach then The effect of changing in the inlet turbine temperature on the exergy efficiency and exergy destruction in this plant was evaluated. The results show that the exergy efficiency of the combustion chamber is much lower than that of other plant components due to chemical reaction and the large temperature difference between the burners and working fluid. In addition, these calculations are performed for 50 and 75% G.T base load and results show that the exergy destruction when G.T work in base load is more than full load
Keywords:
Authors
Amir Farhad Najafi
Assistant Professor Power and Water University of Technology Energy Engineering Department
Pouria Ahmadi
M. Sc Student Iran University of Science &Technology Mechanical
Abdosaeid Ganjehei kaviri
M. Sc Student-Iran University of Science &Technology
مراجع و منابع این Paper:
لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :