Methodology and Case Study of Optimum Prover Sizing for an Ultrasonic Fiscal Metering System of Crude Oil
Publish place: Third National Conference on Fluid Flow Measurement in Oil, Gas, Refining, Petrochemical and Water Industries
Publish Year: 1395
نوع سند: مقاله کنفرانسی
زبان: English
View: 356
This Paper With 12 Page And PDF Format Ready To Download
- Certificate
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
FLOWMEASUREMENT03_027
تاریخ نمایه سازی: 13 شهریور 1396
Abstract:
This paper presents a procedure in format of a flowchart for prover sizing based on API-MPMS Standard which can be considered as a pattern for prover sizing in field prover design and fabrication. The method was analyzed and verified for the prover of the biggest crude oil fiscal metering system in Iran, i.e. bidirectional field prover of Genaveh Million BBL Crude Oil Storage Tanks Fiscal Metering System Project which was designed and fabricated by Asia Instruments Co. LTD. Since this metering system comprises ten Faure Herman Ultrasonic liquid flow meters, API MPMS standard requirements for ultrasonic liquid meters were also considered in prover sizing presented method. Results indicate how optimum prover dimensions can be obtained based on project specifications and other equipment of metering system and prover
Keywords:
Authors
Majid Razaghi
Project Manager, Asia Instruments Co. LTD