SOIL CATEGORY EFFECTS ON THE PERFORMANCE POINT OF STEEL FRAMED TUBE TALL STRUCTURES EQUIPPED WITH BELT TREUSSES AND ADDITIONAL ISOLATED UPPER FLOORS (AIUF)
Publish place: The 6th National Conference and the 2nd International Conference on Civil Engineering Materials and Structures
Publish Year: 1396
نوع سند: مقاله کنفرانسی
زبان: English
View: 497
This Paper With 8 Page And PDF Format Ready To Download
- Certificate
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
NCNMS06_021
تاریخ نمایه سازی: 22 دی 1396
Abstract:
Current research is carried out on Steel Framed Tube Tall Structures with Truss Belts, consisting welded connections. The main aim is to illustrate the effects of soil categories on the Performance Point of such structures, when using Seismic Base Isolation System under the top stories. For this purpose, 5 three dimensional 40~60 stories Framed Tube Structures, equipped with belt trusses are modeled, analyzed and designed according to ASCE 7-10 code, based on 3 soil categories of Rock (800Capacity Spectrum and Performance Point characteristics due to related soil categories are computed for each model, using USB97 pseudo-acceleration spectrums.
Keywords:
Additional Isolated Upper Floor , Framed Tube Tall Structures , Performance Point , Modal Pushover Analysis , Capacity Spectrum
Authors
Armen Assatourians
Earthquake Engineering Research Consultant, Yerevan Project Co., Yerevan, Armenia
Sohrab Fallahi
Senior Structural Designer, E.S.S. Consulting Eng. Co., Tehran, Iran
Mohammad Reza Mehrdoust
Earthquake Engineer, Head of North and North-East branch of BHRC , Mashhad, Iran