Composite Wrap for Non-Leaking Piping Defects of Under Ground Pipe

Publish Year: 1397
نوع سند: مقاله کنفرانسی
زبان: English
View: 420

This Paper With 15 Page And PDF Format Ready To Download

  • Certificate
  • من نویسنده این مقاله هستم

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این Paper:

شناسه ملی سند علمی:

MECHAERO03_377

تاریخ نمایه سازی: 5 آبان 1397

Abstract:

In this research for a defect in a pipeline is intruduced then a geometry for repairing composite is proposed. By simulating with ABAQUS CAE the structure is designed. For investigating of failure, Hashin s theory is employed and Araldite 2015A/B Adhesive is introduced. In order to obtain the best layup and minimum stress distribution, ten stacking sequence is studied. According to ASME B31.8 for different region safety factor, number of lamina and thickness is calculated. Eventually graph of stress distributions for 11 22 ,  and 12 is drawn.

Authors

MohammadSadegh Fayez

Department of Piping Engineering, Monenco Engineering Consultant , Tehran, Iran