سیویلیکا را در شبکه های اجتماعی دنبال نمایید.

Simplified Dynamic Phantom for Pediatric Renography: A Description of Instrument and Its Performance

Publish Year: 1398
Type: Journal paper
Language: English
View: 352

This Paper With 11 Page And PDF Format Ready To Download

Export:

Link to this Paper:

Document National Code:

JR_JNMB-7-1_006

Index date: 3 July 2019

Simplified Dynamic Phantom for Pediatric Renography: A Description of Instrument and Its Performance abstract

Objective(s): Renography is used for the diagnostic evaluation of pediatric patients with a suspected obstruction of urinary tract or impaired renal function. The recommended dose for children have been released by the European Association of Nuclear Medicine, Society of Nuclear Medicine and Molecular Imaging, and Japanese Society of Nuclear Medicine. Since acquisition counts in dynamic scintigraphy are affected by the administered doses and sensitivity of the scintillation camera, the scan procedure should be determined independently. In this study, we constructed simplified dynamic phantom imitating pediatric renography and tested its performance.Methods: Simplified dynamic phantom consisted of three components (i.e.,infusion, imitated kidney, and drainage sections). The infusion rates (mL/min) were determined by comparing the time activity curves obtained from patientswith normal renal function. The time-points of the maximum counts (Tmax), as well as the two-thirds and one-half of the maximum counts (T2/3 and T1/2) were measured in different doses using the phantom with the best-match infusion rateand duration, and low-energy general-purpose (LEGP) or low-energy highresolution (LEHR) collimators and applying different attenuations.Results: The best-match infusion rates of the phantom to imitate the time activity curve of the normal renal function were 42.0, 1.0, 0.6, and 0.3 mL/min in the arterial, secretory, early-excretory, and late-excretory phases, respectively. When 30 MBq, LEHR collimator and non-water-equivalent phantom were applied, Tmax, T2/3, and T1/2 were 242±15.3, 220±10.0 and 317±25.2 seconds, respectively. Using LEGP collimator and (3 MBq of activity) 5-cm water-equivalent phantom, Tmax, T2/3, and T1/2 values were estimated as 242±5.8, 213±11.5, and 310±17.3 sec, respectively.Conclusion: Our simplified dynamic phantom for pediatric renography could imitate the time activity curves obtained from patients with normal renal function. Tmax, T2/3, and T1/2 could be measured under various settings of dose,collimator, and tissue attenuation.

Simplified Dynamic Phantom for Pediatric Renography: A Description of Instrument and Its Performance Keywords:

Simplified Dynamic Phantom for Pediatric Renography: A Description of Instrument and Its Performance authors

Takashi Kamiya

Osaka University Hospital

Tadashi Watabe

Department of Nuclear Medicine and Tracer Kinetics, Osaka University Graduate School of Medicine

Koichi Fujino

Osaka University Hospital

Romanov Victor

Osaka University Graduate School of Medicine

مراجع و منابع این Paper:

لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :
O’Reilly P, Aurell M, Britton K, Kletter K, Rosenthal L, ...
Taylor A, Nally J, Aurell M, Blaufox M, Dondi M, ...
Boubaker A, Prior JO, Meuwly JY, Bischof-Delaloye A. Radionuclide investigations ...
Asaidi M, Eftekhari M, Hozhabrosadati M, Saghari M, Ebrahimi A, ...
Ilhan H, Wang H, Gildehaus F, Wangler C, Herrler T, ...
Blum ES, Porras AR, Biggs E, Tabrizi PR, Sussman RD, ...
Fahey FH, Bom HH, Chiti A, Choi YY, Hunag G, ...
Fahey FH, Bom HH, Chiti A, Choi YY, Hunag G, ...
Gordon I, Piepsz A, Sixt R; Auspices of Paediatric Committee ...
Lassmann M, Biassoni L, Monsieurs M, Franzius C, Jacobs F. ...
Gelfand MJ, Parisi MT, Treves ST; Pediatric Nuclear Medicine Dose ...
Koizumi K, Masaki H, Matsuda H, Uchiyama M, Okuno M, ...
Heikkinen JO. New automated physical phantom for renography. J Nucl ...
Sabbir Ahmed AS, Demir M, Kabasakal L, Uslu I. A ...
Karagoz I, Erogul O. A new dynamic renal phantom and ...
Nykanen AO, Rautio PJ, Aarnio JV, Heikkinen JO. Multicenter evaluation ...
Esteves PF, Taylor A, Manatunga A, Folks RD, Krishnan M, ...
Ikekubo K, Hino M, Ito H, Yamamoto K, Torizuka K. ...
Ishii K, Ishibashi A, Torizuka K. Phase I clinical study ...
Taylor A, Eshima D, Fritzberg AR, Christian PE, Kasina S. ...
Gibson P, Shammas A, Cada M, Licht C, Gupta AA. ...
Hubertus J, Plieninger S, Martinovic V, Heinrich M, Schuster T, ...
Hsiao EM, Cao X, Zurakowski D, Zukotynski KA, Drubach LA, ...
Smith T, Zanelli D, Veall N. Radiation absorbed dose from ...
Hazar V, Gungor O, Guven AG, Aydin F, Akbas H, ...
Filler G, Sharma AP. How to monitor renal functions in ...
Boubaker A, Prior JO, Meyrat B, Bischof Delaloye A, McAleer ...
نمایش کامل مراجع