A study on slab-wooden dust-slab phantom for the development of thorax phantom
Publish place: Iranian Journal of Medical Physics، Vol: 15، Issue: 2
Publish Year: 1397
نوع سند: مقاله ژورنالی
زبان: English
View: 317
This Paper With 7 Page And PDF Format Ready To Download
- Certificate
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_IJMP-15-2_002
تاریخ نمایه سازی: 18 تیر 1398
Abstract:
Introduction: The determination of accurate dose distribution is an issue of fundamental importance in radiotherapy, especially with regard to the fact that the human body is a heterogeneous medium. Therefore, the present study aimed to analyze the density and isodose depth profiles of 6 MV beam in a SP34 slab-wooden dust (pine)-SP34 slab (SWS) heterogeneous phantom.
Materials and Methods: The density of SP34 slab, wooden dust of pine, and thoracic region of 10 patients were calculated using computed tomography (CT) images. The depths of isodose lines were measured for 6 MV beam on the CT images of the chest, SP34 slab phantom, and SWS phantom. Dose calculation was performed at the depths of 2, 13, and 21 cm in both phantoms. Furthermore, patient-specific quality assurance (QA) was implemented using both phantoms.
Results: The mean densities of the lung, SP34 slabs, and wooden dust were 0.29, 0.99, and 0.27 gm/cc respectively. The mean depths of different isodose lines in the SWS phantom were found to be equivalent to those in actual patients. Furthermore, the percentage variation between the planned and measured doses was higher in the SWS phantom as compared to that in the SP34 phantom. Furthermore, the percentage variation between the planned and measured doses in patient-specific QA was higher in the SWS phantom as compared to that in the SP34 phantom.
Conclusion: As the findings indicated, the density and isodose depth profiles of the SWS phantom were equivalent to those of the actual thoracic region of human.
Keywords:
Hounsfield number , patient specific quality assurance , SP34 slab phantom , thorax phantom , SWS phantom
Authors
Priyusha Bagdare
PhD Scholar School of Studies in Physics, Vikram University, Ujjain ۴۵۶۰۱۰, India
Swati Dubey
Associate Professor School of Studies in Physics Vikram University, Ujjain (M.P.) ۴۵۶۰۰۱
Sanjay Kumar Ghosh
Professor & Head School of Studies in Physics Vikram University, Ujjain (M.P.) ۴۵۶۰۰۱
Om Prakash Gurjar
Roentgen-SAIMS Radiation Oncology Centre, Sri Aurobindo Institute of Medical Sciences, Indore (MP), India
مراجع و منابع این Paper:
لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :