Evaluation of Effect of Different Computed Tomography Scanning Protocols on Hounsfield Unit and Its Impact on Dose Calculation by Treatment Planning System

Year: 1396
COI: JR_IJMP-14-3_005
Language: EnglishView: 141
This Paper With 6 Page And PDF Format Ready To Download

Buy and Download

با استفاده از پرداخت اینترنتی بسیار سریع و ساده می توانید اصل این Paper را که دارای 6 صفحه است به صورت فایل PDF در اختیار داشته باشید.
آدرس ایمیل خود را در کادر زیر وارد نمایید:

Authors

Mamta Mahur - Department of Radiotherapy, Delhi State Cancer Institute(s), Dilshad Garden, Delhi – ۱۱۰۰۹۵, India
Om Prakash Gurjar - Roentgen-SAIMS Radiation Oncology Centre, Sri Aurobindo Institute of Medical Sciences
RK GROVER - Department of Radiotherapy, Delhi State Cancer Institute(s), Dilshad Garden, Delhi – ۱۱۰۰۹۵, India
PS Negi - Department of Radiotherapy, Delhi State Cancer Institute(s), Dilshad Garden, Delhi – ۱۱۰۰۹۵, India

Abstract:

Introduction: In radiotherapy treatment planning system (TPS), basic input is the data from computed tomography (CT) scan, which takes into account the effect of inhomogeneities in dose calculations. Measurement of CT numbers may be affected by scanner-specific parameters. Therefore, it is important to verify the effect of different CT scanning protocols on Hounsfield unit (HU) and its impact on dose calculation. This study was carried out to analyse the effect of different tube voltages on HU for various tissue substitutes in phantom and their dosimetric impact on dose calculation in TPS due to variation in HU–relative electron density (RED) calibration curves. Materials and Methods: HU for different density materials was obtained from CT images of the phantom acquired at various tube voltages. HU-RED calibration curves were drawn from CT images with various tissue substitutes acquired at different tube voltages used to quantify the error in dose calculation for different algorithms. Doses were calculated on CT images acquired at 120 kVp and by applying CT number to RED curve obtained from 80, 100, 120, and 140 kVp voltages. Results: No significant variation was observed in HU of different density materials for various kVp values. Doses calculated with applying different HU-RED calibration curves were well within 1%. Conclusion: Variation in doses calculated by algorithms with various HU-RED calibration curves was found to be well within 1%. Therefore, it can be concluded that clinical practice of using the standard HU-RED calibration curve by a 120 kVp CT acquisition technique is viable.

Keywords:

Computed Tomography Hounsfield Units , Phantom , Treatment Planning System

Paper COI Code

This Paper COI Code is JR_IJMP-14-3_005. Also You can use the following address to link to this article. This link is permanent and is used as an article registration confirmation in the Civilica reference:

https://civilica.com/doc/893277/

How to Cite to This Paper:

If you want to refer to this Paper in your research work, you can simply use the following phrase in the resources section:
Mahur, Mamta and Gurjar, Om Prakash and GROVER, RK and Negi, PS,1396,Evaluation of Effect of Different Computed Tomography Scanning Protocols on Hounsfield Unit and Its Impact on Dose Calculation by Treatment Planning System,https://civilica.com/doc/893277

مراجع و منابع این Paper:

لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :

  • Watanabe Y. Derivation of linear attenuation coefficients from CT numbers ...
  • Das IJ, Cheng CW, Cao M, Johnstone PAS. Computed tomography ...
  • Roa AMA, Andersen HK, Martinsen AC. CT image quality over ...
  • Constantinou C, Harrington JC, DeWerd LA. An electron density calibration ...
  • Guan H, Yin FF, Kim JH. Accuracy of inhomogeneity correction ...
  • Moyers MF, Miller DW, Siebers JV, Galindo R, Sun S, ...
  • Nobah A, Moftah B, Tomic N, Devic A. Influence of ...
  • Goodenough DJ. Catphan 500 and 600 manual. Greenwich, NY: The ...
  • Sande EP, Martinsen AC, Hole EO, Olerud HM. Inter phantom ...
  • Cozzi L, Fogliata A, Buffa F, Bieri S. Dosimetric impact ...
  • Sharma DS, Sharma SD, Sanu KK, Saju S, Deshpande DD, ...
  • Cropp RJ, Seslija P, Tso D, Thakur Yogesh. Scanner and ...
  • Maria AR, Anderson HK, Martinsen AC. CT image quality over ...
  • Gulliksurd K, Stokke C, Martinsen AC. How to measure CT ...

Research Info Management

Certificate | Report | من نویسنده این مقاله هستم

اطلاعات استنادی این Paper را به نرم افزارهای مدیریت اطلاعات علمی و استنادی ارسال نمایید و در تحقیقات خود از آن استفاده نمایید.

Share this page

More information about COI

COI stands for "CIVILICA Object Identifier". COI is the unique code assigned to articles of Iranian conferences and journals when indexing on the CIVILICA citation database.

The COI is the national code of documents indexed in CIVILICA and is a unique and permanent code. it can always be cited and tracked and assumed as registration confirmation ID.

Support