Seismic performance assessment of Strong-back braced frames at collapse level
Publish place: 3rd International Conference on Applied Researches in Structural Engineering and Construction Management (secm2019)
Publish Year: 1398
نوع سند: مقاله کنفرانسی
زبان: English
View: 617
This Paper With 8 Page And PDF Format Ready To Download
- Certificate
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
SECM03_145
تاریخ نمایه سازی: 9 شهریور 1398
Abstract:
In prescriptive seismic design codes, quantification of seismic performance factors (R, Ω, Cd) for new structural systems is decisive step. One of the recent introduced structural bracing systems is called Strong-Back System (SBS), which is a hybrid of a conventional inelastic system and an essentially elastic steel truss designed to distribute demands uniformly. The purpose of this study is to evaluate these factors for SBS. To this end, series of nonlinear static and dynamic analyses are conducted and the derived parameters are compared with the accepted values proposed by FEMA-P695. The results indicated that R=6 can be appropriate value for SBS
Keywords:
Authors
Mohammadreza Salek Faramarzi
MSc Student, Amirkabir university of technology, Tehran, Iran
Touraj Taghikhany
Associate Professor, Amirkabir university of technology, Tehran, Iran