CenoDerm vs. Fascia lata for the Prevention of Dorsal Nasal Irregularities in Rhinoplasty
Publish place: Iranian Journal of Otorhinolaryngology، Vol: 28، Issue: 4
Publish Year: 1395
نوع سند: مقاله ژورنالی
زبان: English
View: 335
This Paper With 8 Page And PDF Format Ready To Download
- Certificate
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_IJOTO-28-4_001
تاریخ نمایه سازی: 21 مهر 1398
Abstract:
Introduction: Dorsal nasal irregularity is a complication of rhinoplasty surgery, mostly seen in patients with thin skin. Acellular dermis (CenoDerm) and homologous fascia lata covering the nasal bone cartilage structure have been used to achieve a smooth surface. In this study, we aimed to investigate clinical outcomes using these two materials. Materials and Methods: After a standard rhinoplasty procedure, a layer of the acellular dermis or homologous fascia lata was placed in the pocket of the dorsum. Patients were evaluated for clinical outcomes at 3, 6, and 12 months after the procedure. Results: Forty-two of 68 patients completed the follow-up period. Patient satisfaction was higher in the homologous fascia lata group. Similarly, nasal dorsum inspection and palpation results were better in the homologous fascia lata group compared with the CenoDerm group but was significant in palpation (P=0.00). There was no complete absorption in the homologous fascia lata group 6 months after surgery (P= 0.04 vs. CenoDerm) but no significant difference was observed at 12 months. Conclusion: Homologous fascia lata is better than acellular dermis in preventing dorsal nasal irregularity after rhinoplasty in thin-skinned patients.
Keywords:
Authors
Alireza Mohebbi
Otolaryngology Research Center, Rasoul Akram Hospital, Iran University of Medical Sciences, Tehran, Iran.
Roghayeh Hamidian
Department of Otolaryngology, Rasoul Akram Hospital, Iran University of Medical Sciences, Tehran, Iran.
Seyed Behzad Poosti
Otolaryngology Research Center, Rasoul Akram Hospital, Iran University of Medical Sciences, Tehran, Iran.
Seyedeh Simindokht Hosseini
Eye Research Center, Farabi Eye Hospital, Tehran University of Medical Sciences, Tehran, Iran.
مراجع و منابع این Paper:
لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :