سیویلیکا را در شبکه های اجتماعی دنبال نمایید.

Monte Carlo-based optimization of a gamma probe system for sentinel lymph node mapping

Publish Year: 1398
Type: Journal paper
Language: English
View: 370

This Paper With 7 Page And PDF Format Ready To Download

Export:

Link to this Paper:

Document National Code:

JR_IRJNM-27-1_002

Index date: 8 February 2020

Monte Carlo-based optimization of a gamma probe system for sentinel lymph node mapping abstract

Introduction: Sentinel lymph node biopsy (SLNB) is a standard surgical technique to identify sentinel lymph node (SLN) for the staging of early breast cancer. Nowadays, two methods are used for the identification of SLN: blue dye method aiding visually and radioactive dye using gamma detector. A wide range of gamma probe systems with different design and performance are used in intra-operative surgery. The performance of the probes is evaluated by some parameters such as sensitivity, spatial resolution, angular resolution, and shielding efficiency. Methods: In this study, we simulated a gamma probe system, SURGEOGUIDE II based on CsI(Tl) scintillator, a silicon photomultiplier (SiPM), and a tungsten collimator, using the MCNP4C Monte Carlo (MC) method and comparing with experimental measurement. Finally we modeled a series of probe with various crystal material, crystal length, and collimator hole length to evaluate the sensitivity and the spatial resolution in order to propose the optimal configuration. Results:The sensitivity of the system was measured as 2040 cps/MBq in 30 mm distance from the source. The spatial resolution and angular resolution were 43 mm and  at the same distance, respectively. Sensitivity at 30 mm distance from the probe head was the highest for BGO crystal and was the lowest for NaI crystals. The sensitivity and spatial resolution have also been changed by increasing the length of the crystal to a certain amount and then remained constant. Conclusion: The results showed that the best choice for crystal was CdTe and CsI and the best length for CsI crystal in this type of the systems was 10 mm long. Also, based on the specific application, special probe should be designed taking the length of the collimator hole into consideration.

Monte Carlo-based optimization of a gamma probe system for sentinel lymph node mapping Keywords:

Monte Carlo-based optimization of a gamma probe system for sentinel lymph node mapping authors

Azadeh Nikoogoftar

Faculty of Nuclear Engineering and Physics, Amirkabir University of Technology, Tehran, Iran|Research Centre for Molecular and Cellular Imaging, Tehran University of Medical Sciences, Tehran, Iran

Mojtaba Shamsaie

Faculty of Nuclear Engineering and Physics, Amirkabir University of Technology, Tehran, Iran

Navid Zeraatkar

Department of Radiology, University of Massachusetts Medical School, Worcester, MA, USA

Mohammad Reza Ay

Research Centre for Molecular and Cellular Imaging, Tehran University of Medical Sciences, Tehran, Iran|Department of Medical Physics and Biomedical Engineering, Tehran University of Medical Sciences, Tehran, Iran

مراجع و منابع این Paper:

لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :
Osako T, Iwase T, Kimura K, Yamashita K, Horii R, ...
Cheng G, Kurita S, Torigian DA, Alavi A. Current status ...
Gipponi M, Bassetti C, Canavese G, Catturich A, Di Somma ...
Kootstra JJ, Dijkstra PU, Rietman H, de Vries J, Baas ...
Ahmed M, Purushotham AD, Douek M. Novel techniques for sentinel ...
Chen SL, Iddings DM, Scheri RP, Bilchik AJ. Lymphatic mapping ...
Gould EA, Winship T, Philbin PH, Kerr HH. Observations on ...
Tanis PJ, Nieweg OE, Valdés Olmos RA, Th Rutgers EJ, ...
Myers WG, Vanderleeden JC. Radioiodine-125. J Nucl Med. 1960 Jul;1:149-64. ...
Cengić T, Corluka S, Petrović T, Baranović S, Kovacić K, ...
Wydra D, Matuszewski R, Romanowicz G, Bandurski T. Evaluation of ...
Rogers DW. Fifty years of Monte Carlo simulations for medical ...
Buvat I, Castiglioni I. Monte Carlo simulations in SPET and ...
De Vries DJ, Moore SC, Zimmerman RE, Mueller SP, Friedland ...
Yanch JC, Dobrzeniecki AB. Monte Carlo simulation in SPECT:complete 3D ...
Lorincz E, Erdei G, Péczeli I, Steinbach C, Ujhelyi F, ...
Sarrut D, Bardiès M, Boussion N, Freud N, Jan S, ...
National Electrical Manufacturers Association. NEMA Standards Publication NU 3-2004. Performance ...
Ay MR, Zeraatkar N, Gorjizadeh N, Kaviani A, Farzaneh Far ...
Kaviani S, Zeraatkar N, Sajedi S, Gorjizadeh N, Farahani M, ...
Kroese DP, Brereton T, Taimre T, Botev ZI. Why the ...
Tiourina T, Arends B, Huysmans D, Rutten H, Lemaire B, ...
Mariani G, Vaiano A, Nibale O, Rubello D. Is the ...
Sarikaya I, Sarikaya A, Reba RC. Gamma probes and their ...
Bolozdynya A, Vorobiev K, Evgrafova E, Zhukov K, Kantserov V, ...
Classe JM, Fiche M, Rousseau C, Sagan C, Dravet F, ...
Halkar RK, Aarsvold JN. Intraoperative probes. J Nucl Med Technol. ...
نمایش کامل مراجع