A study on differentiation of extra-cardiac activity by Slit Slat collimation in Single Photon Emission Computed Tomography

Publish Year: 1397
نوع سند: مقاله ژورنالی
زبان: English
View: 336

This Paper With 8 Page And PDF Format Ready To Download

  • Certificate
  • من نویسنده این مقاله هستم

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این Paper:

شناسه ملی سند علمی:

JR_IRJNM-26-1_005

تاریخ نمایه سازی: 21 بهمن 1398

Abstract:

Introduction: Myocardial perfusion SPECTby 99mTc-Sestamibi and 99mTc-Tetrofosmin radiopharmaceuticals usually presents a false significant increase in the radiotracer uptake in the inferior myocardium due to the uptake in organs such as liver, bowel, stomach and biliary system. The present study evaluated a suitable Slit angle for differentiating extra-cardiac activities by Slit Slat collimation. Methods: The Siemens E.CAM gamma camera equipped with a Low Energy High Resolution (LEHR) collimator was simulated with the Simulating Medical Imaging Nuclear Detectors (SIMIND) Monte Carlo program. Following the verification of the simulation, a Slit Slat collimator was simulated for SPECT imaging of a NURBS-based Cardiac Torso (NCAT) phantom with different Slit angels ranged from 0 to 30 degrees. The reconstructed images were qualitatively assessed with blinded observer method by three nuclear medicine specialists. Results:The improved differentiation of the bowel activity from the cardiac was obtained by a Slit-Slat collimator with the Slit angle of 7 degree. While for gastric activity differentiation an angle of 15 degree for the Slit was useful. Conclusion: The results showed that Slit Slat collimation with 7 and 15 Slit angle provide a suitable differentiation of the bowel and gastric activities from the cardia, respectively.

Authors

Parvaneh Darkhor

Immunology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran

Babak Mahmoudian

Departments of Radiology, Tabriz University of Medical Sciences, Tabriz, Iran

Esmaeil Gharepapagh

Departments of Radiology, Tabriz University of Medical Sciences, Tabriz, Iran

Seyed Rasoul Zakavi

Nuclear Medicine Research Center, Mashhad University of Medical Sciences, Mashhad, Iran

مراجع و منابع این Paper:

لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :
  • Liu C, Xu J, Tsui BM. Myocardial perfusion SPECT using ...
  • Caobelli F, Kaiser SR, Thackeray JT, Bengel FM, Chieregato M, ...
  • Armstrong IS, Saint KJ, Tonge CM, Arumugam P. Evaluation of ...
  • Onishi H, Matsutomo N, Kangai Y, Saho T, Amijima H. ...
  • Chen X, Guo Y, Zhang Q, Hao G, Jia H, ...
  • Rojas G, Raff U, Gonzalez P, Jaimovich R, Quintana JC. ...
  • Kim YS, Wang J, Broisat A, Glover DK, Liu S. ...
  • Peace RA, Lloyd JJ. The effect of imaging time, radiopharmaceutical, ...
  • Branderhorst W, van der Have F, Vastenhouw B, Viergever MA, ...
  • Adamson K. Principles of myocardial SPECT imaging. In: Movahed A, ...
  • Hofman M, McKay J, Nandurkar D. Efficacy of milk versus ...
  • Afzelius P, Henriksen JH. Extra cardiac activity detected on myocardial ...
  • Gholamrezanezhad A, Moinian D, Eftekhari M, Mirpour S, Hajimohammadi H. ...
  • Smith MF. Recent advances in cardiac SPECT instrumentation and system ...
  • Dehestani N, Sarkar S, Ay MR, Sadeghi M, Shafaei M. ...
  • Bal G, Clackdoyle R, Kadrmas DJ, Zeng GL, Christian PE. ...
  • Metzler SD, Accorsi R, Novak JR, Ayan AS, Jaszczak RJ. ...
  • Cao L, Peter J. Slit-slat collimator equipped gamma camera for ...
  • Caobelli F, Thackeray JT, Soffientini A, Bengel FM, Pizzocaro C, ...
  • Chang W, Ordonez CE, Liang H, Li Y, Liu J. ...
  • Rogers WL, Clinthorne NH, Stamos J, Koral KF, Mayans R, ...
  • DePuey EG. Advances in SPECT camera software and hardware: currently ...
  • Slomka PJ, Patton JA, Berman DS, Germano G. Advances in ...
  • Ljungberg M, Strand SE, King MA. The SIMIND Monte Carlo ...
  • Kau D, Metzler SD. Finding optimized conditions of slit-slat and ...
  • Ghaly M, Du Y, Fung GS, Tsui BM, Links JM, ...
  • Holly TA, Abbott BG, Al-Mallah M, Calnon DA, Cohen MC, ...
  • Bahreyni Toossi MT, Islamian JP, Momennezhad M, Ljungberg M, Naseri ...
  • Kalantari F, Rajabi H, Yaghoobi N. Optimized energy window configuration ...
  • Saad IE, Helal NL, El-Din HM, Moneam RA. Evaluation of ...
  • NEMA NU 1-2012 Performance Measurements of Gamma Cameras. The National ...
  • Piccinelli M, Garcia EV. Advances in software for faster procedure ...
  • Yussoff MS, Zakaria A. Relationship between the optimum cut off ...
  • Esser PD, Alderson PO, Mitnick RJ, Arliss JJ. Angled-collimator SPECT ...
  • Sheng J. An elliptical SPECT system with slit-slat collimation for ...
  • نمایش کامل مراجع