سیویلیکا را در شبکه های اجتماعی دنبال نمایید.

Applying the logistic regression model to predict the carotid artery stenosis using the sequential color Doppler ultrasound image processing

Publish Year: 1383
Type: Conference paper
Language: English
View: 1,836

This Paper With 6 Page And PDF Format Ready To Download

این Paper در بخشهای موضوعی زیر دسته بندی شده است:

Export:

Link to this Paper:

Document National Code:

ICMVIP03_043

Index date: 14 October 2011

Applying the logistic regression model to predict the carotid artery stenosis using the sequential color Doppler ultrasound image processing abstract

Early detection of stenosis in carotid artery is essential because it directly affects patients' clinical management and is prognostic value. Therefore, estimating of mechanical properties of artery in normal and atherosclerosis are important as far as the medical treatment is concern. We applied a logistic regression model to predict the carotid artery stenosis in a group of patients based on the quantitative features extracted from the processing of the conventional color Doppler ultrasound images. Our database includes 128 patients' records consisting 10 quantitative features. The database is then randomly divided into the training and validation samples including 98 and 30 patients' records respectively. The training and validation samples are used to construct the logistic regression model and to validate its performance. Finally, important criteria such as sensitivity, specificity, accuracy and receiver operating characteristic curve (ROC) analysis for this method are evaluated. Our results show that the logistic regression model is able to classify correctly 28 out of 30 cases presented in the validation sample. The output of this method showed a high positive predictive value of 0.94%.

Applying the logistic regression model to predict the carotid artery stenosis using the sequential color Doppler ultrasound image processing Keywords:

Applying the logistic regression model to predict the carotid artery stenosis using the sequential color Doppler ultrasound image processing authors

P. Abdolmaleki

Tarbiat Modarres University

M. Mokhtari-Dizaji

Tarbiat Modarres University

M. Montazeri

Shiraz Medical Sciences Univ

H. Saberi

Tehran Medical Sciences Univ

مراجع و منابع این Paper:

لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :
M.B. Johnson, I.D. Willkinson, J. wattam, et al. "Comparisn of ...
angiographic techniques and catheter angiography in evaluation of carotid stenosis" ...
J.N. Cohn. "New approaches to screening for vascular and cardiac ...
C.E. Metz. "Some practical issues of experimental design and data ...
C.E. Metz. "ROC methodology in radiologic imaging" Invest Radiol Vol. ...
_ 'Noninva sive vascular ultrasound: an asset in vascular medicine". ...
L.H. Peterson, R.E. Jensen, J. Parnell. Mechanical properties of arteries ...
rd MVIP, Feb. 2005, Vol. 1 ...
نمایش کامل مراجع