Study of Thermal-Hydraulic Performance in a Spiral Channel Equipped with Twisted-Tape Insert Using Computational Fluid Dynamics
Publish Year: 1400
نوع سند: مقاله کنفرانسی
زبان: English
View: 259
This Paper With 7 Page And PDF Format Ready To Download
- Certificate
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
NCFDACCI10_025
تاریخ نمایه سازی: 5 بهمن 1400
Abstract:
In this study, the thermal-hydraulic performance (THP) of the straight channel, spiral channel (SC), and spiral channel equipped with twisted-tape insert (SCT) was studied using computational fluid dynamics (CFD). The flow path length and hydraulic diameter in all channels were ۱.۳۸۲۳ and ۰.۰۱ m, respectively, and the cross-section of the channels was selected as circular. Simulations were performed for turbulent flow regime and Reynolds Number (Re)=۱۰۰۰۰-۵۰۰۰۰. The working fluid was liquid water and the temperature of the inlet fluid and the wall channel were assumed to be constant at ۲۹۸ and ۳۵۳ K, respectively. According to the results, SCT had the best thermal performance but the best thermal-hydraulic performance was obtained for SC.
Keywords:
Heat Exchanger , Spiral Channel , Twisted-Tape Insert , Thermal-Hydraulic Performance (THP) , Computational Fluid Dynamics (CFD)
Authors
Reza Beigzadeh
Department of Chemical Engineering, Faculty of Engineering, University of Kurdistan, Sanandaj, Iran
Saeid Salimi
Department of Chemical Engineering, Faculty of Engineering, University of Kurdistan, Sanandaj, Iran