سیویلیکا را در شبکه های اجتماعی دنبال نمایید.

Concordance and Diagnostic Accuracy of Ultrasonography and Mammography Findings with Pathology Results in Breast Cancer

Publish Year: 1399
Type: Journal paper
Language: English
View: 212

This Paper With 5 Page And PDF Format Ready To Download

این Paper در بخشهای موضوعی زیر دسته بندی شده است:

Export:

Link to this Paper:

Document National Code:

JR_ARCHB-7-3_007

Index date: 31 October 2022

Concordance and Diagnostic Accuracy of Ultrasonography and Mammography Findings with Pathology Results in Breast Cancer abstract

Background: Ultrasonography and mammography are two radiologicapproaches for screening breast cancer; however, the pathology report is requiredfor the ultimate diagnosis of malignancy. This study aimed to assess theconcordance of ultrasonography (US) and mammography with the pathology inbreast cancer. Methods: A cross-sectional study was conducted to assess the breast US andthe mammography findings based on the BI-RADS model in comparison with thedefinitive pathology reports in a single medical center. The sensitivity, thespecificity, positive (PPV) and negative predictive value (NPV) and also theconcordance between the US and the mammography data were analyzed. Results: In this study, 126 patients were included. The sensitivity, specificity,PPV, and NPV for the US were 69.8, 71.9, 75.6 and 81.3 and for mammographywere 91.9, 76.6, 80.8 and, 94.6 percent, respectively. The ROC-curve for either theUS or the mammography showed that the BI-RADS 4 was accompanied with thehighest sensitivity and specificity for the screening of the malignant breast lesionsregarding the final diagnosis. Although an overall higher correlation betweenmammography report and presence of a malignant lesion was observed, the totalrelative concordance between the results of US and mammography as screeningtools proved to be statistically significant (P<0.01). Conclusion: Both the US and the mammography were sensitive and specificscreening tools, particularly for the malignant breast lesions. Furthermore, whenevidence of the BI-RADS≥4 in either the mammography or the US was present,utilization of the other test could be ignored before biopsy.

Concordance and Diagnostic Accuracy of Ultrasonography and Mammography Findings with Pathology Results in Breast Cancer Keywords:

Concordance and Diagnostic Accuracy of Ultrasonography and Mammography Findings with Pathology Results in Breast Cancer authors

Leila Ghafoor

Department of General Surgery, Kashan University of Medical Sciences, Kashan, Iran

Abbas Hajian

Department of General Surgery, Kashan University of Medical Sciences, Kashan, Iran

Yaser Hamidian

Department of Radiology, Kashan University of Medical Sciences, Kashan, Iran

Seyed Hamed Rohani

Department of General Surgery, Kashan University of Medical Sciences, Kashan, Iran