Performance analysis of a geothermal organic rankine cycle (ORC) with two-phase closed thermosyphone abstract
In this paper, an enhanced FORTRAN code was combined with the EES software to develop thermodynamic model and exergy analysis of a twophase closed thermosyphon system to generation electricity in an organic rankine cycle (ORC). Working fluids considered are R134a, R123, R22, Water, and ammonia. Energy balance is carried out to predictoperating conditions of the process. Output of energy balance are used as input for exergy analysis and components of ORC. We also calculated the extraction rate for different lengths of evaporator heat pipe and different temperatures of the geothermal temperature range of 50-200°C. Finally the energy, Exergy distruction ratio and net work output for different working fluids is comparable.