سیویلیکا را در شبکه های اجتماعی دنبال نمایید.

Modification of Multi-walled Carbon Nanotubes Composite Paste Electrode with Nanonickel Pentacyanonitrosylferrate and Nickel Oxide Nanoparticles for Non-enzymatic Glucose Determination

Publish Year: 1402
Type: Journal paper
Language: English
View: 189

This Paper With 10 Page And PDF Format Ready To Download

Export:

Link to this Paper:

Document National Code:

JR_ANALCH-10-2_006

Index date: 31 January 2023

Modification of Multi-walled Carbon Nanotubes Composite Paste Electrode with Nanonickel Pentacyanonitrosylferrate and Nickel Oxide Nanoparticles for Non-enzymatic Glucose Determination abstract

A novel non-enzymatic electrochemical sensor with high sensitivity for glucose determination was introduced herein with nickel pentacyanonitrosylferrate (NiPCNF)-modified multi-walled carbon nanotubes (MWCNTs) paste electrode and deposited nickel hydroxide onto paste electrode using NiSO4 solution and H2SO4 as the soft template. The NiO-modified electrode was scanned with cyclic voltammetry (CV) method in alkaline media to obtain Ni(OH)2/NiOOH particles as glucose electrocatalyst. The prepared nickel oxide was then mixed with the paste inside the tube. It was observed that introducing both NiPCNF and NiO could synergistically improve the activity toward electrocatalytic oxidation of glucose with an increase in the accessible active sites and promotion of the electron transport capability. Therefore, the modified electrode did not only exhibit an outstanding electrochemical behavior but also decreased the potential for electrochemical oxidation and enhanced the affinity of the electrode to glucose. Field emission scanning electron microscopy (FESEM) was applied to study the surface morphology of the electrode and prepared NiPCNF powder. After optimizing the condition, the chronoamperometry (CA) technique was applied for glucose determination. Porous-modified electrode, containing both nanomaterials of NiPCNF and NiO, exhibited a vast linear range from 5 µM to 1.95 mM (2.6 orders of magnitude) with a low limit of detection (LOD) of 2.35 × 10-7 ± 1.52×10-8 M (S/N=3) and high sensitivity (2.83 ± 0.17 mA mM-1 cm-2). Finally, the prepared sensor was utilized for glucose determination in the real samples successfully.

Modification of Multi-walled Carbon Nanotubes Composite Paste Electrode with Nanonickel Pentacyanonitrosylferrate and Nickel Oxide Nanoparticles for Non-enzymatic Glucose Determination Keywords:

Modification of Multi-walled Carbon Nanotubes Composite Paste Electrode with Nanonickel Pentacyanonitrosylferrate and Nickel Oxide Nanoparticles for Non-enzymatic Glucose Determination authors

Mahsa Hasanzadeh

Department of Food Safety and Hygiene, School of Health, Fasa University of Medical Sciences, Fasa, Iran. Department of Food and Drug Laboratory, Food and Drug Administration, Urmia University of Medical Sciences, Urmia, Iran

Mehran Sayadi

Department of Food Safety and Hygiene, School of Health, Fasa University of Medical Sciences, Fasa, Iran

Sakineh Alizadeh

Faculty of Chemistry, Bu-Ali Sina University, Hamadan, Iran

Khosrow Ghasemlu

Department of Food and Drug Laboratory, Food and Drug Administration, Urmia University of Medical Sciences, Urmia, Iran