Abstract:

Background: Considering the increased demand for cars in different countries during recent years, using car washes for washing vehicles has received a lot of attention. This study aimed to assess removing chemical oxygen demand (COD) from car wash effluent using the electrocoagulation method. Methods: A reactor with dimensions of ۴۰ cm * ۵۰ cm * ۵۰ cm of Plexiglas with a volume of ۹۰ L equipped with an electric current generator and an electrode was used connected to the DC current generator in the form of Al-Al. The response surface method (RSM) was applied to optimize the factors affecting COD removal in the electrocoagulation process. For this purpose, D-optimal was utilized to optimize the experiments. The effects of measurable factors such as electrolysis time (X۱), current density (X۲), and aeration time (X۳) were examined to check COD removal. Results: According to the results, the optimal operating conditions for COD removal during electrolysis (۳۰ min) were as follow: the current density was ۱۸.۷۵ A/m۲, and the aeration time of ۳۰ min was ۴۸.۵۱%. Conclusion: In conclusion, electrocoagulation is, to some extent, a reliable and environmentally compatible technique for car wash wastewater treatment.

Authors

سید مرتضی موسوی راد

Department of Environment, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman, Iran.

علی حسن زاده سبلوئی

Master of Science in Mining Engineering, Mining and Industry Expert, Bureau of Industry, Mine and Trade of Kerman Province, Kerman, Iran.

مراجع و منابع این Paper:

لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :
  • Panizza M, Cerisola G. Applicability of Electrochemical Methods to Carwash ...
  • Nadzirah Z, Nor Haslina H, Rafidah H. Removal of Important ...
  • Priya M, Jeyanthi J. Removal of COD, Oil and Grease ...
  • Shahidan S, Senin MS, Kadir ABA, Yee LH, Ali N. ...
  • Daneshvar N, Oladegaragoze A, Djafarzadeh N. Decolorization of Basic Dye ...
  • Can OT, Kobya M, Demirbas E, Bayramoglu M. Treatment of ...
  • Zaroual Z, Azzi M, Saib N, Chaînet E. Contribution to ...
  • Merzouk B, Madani Kh, Sekki A. Using Electrocoagulation-Electroflotation Technology to ...
  • Zaied M, Bellakhal N. Electrocoagulation Treatment of Black Liquor from ...
  • Kobya M, Can OT, Bayramoglu M. Treatment of Textile Wastewaters ...
  • Balla W, Essadkia AH, Gouricha B, Dassaa A, Chenik H, ...
  • Bayramoglu M, Kobya M, Can OT, Sozbir M. Operating Cost ...
  • Alinsafi A, Khemis M, Pons MN, Leclerc JP, Yaacoubi A, ...
  • Rahmani A, Samarghandi MR. Electrochemical Removal of COD from Effluents. ...
  • Mehdipoor MA, Moosavirad SM. Effect of the Holed Ferrum Electrodes ...
  • Mollah M, Morkovsky P, Gomes JA, Kesmez M, Parga J, ...
  • Hasanzadeh-Sabloue A, Moosavirad SM. Hardness and Chloride Removal in Dewatering ...
  • Chen G. Electrochemical Technologies in Wastewater Treatment. Sep. Pur. Tech. ...
  • Janssen LJJ, Koene L. The Role of Electrochemistry and Electrochemical ...
  • Acharya S, Sharma SK, Chauhan G, et al. Statistical Optimization ...
  • Sudamalla P, Saravanan P, Matheswaran M. Optimization of Operating Parameters ...
  • Güçlüa D. Optimization of Electrocoagulation of Pistachio Processing Wastewaters Using ...
  • Dindarloo A, Dastoorani M. Evaluation of Effluent Treatment Effluent by ...
  • Montgomery DC, Myers RH, Carter Jr WH, Vining GG. The ...
  • Asaithambi P, Abdul-Aziz A, Wan Daud WM AB. Integrated Ozone-Electrocoagulation ...
  • Huda N, Raman AAA, Bello MM, Ramesh S. Electrocoagulation Treatment ...
  • Moosavirad SM. Increasing Efficiency of Thickener Operation in Concentrate Plant ...
  • Xiarchos I, Jaworska A, Zakrzewska-Trznadel G. Response Surface Methodology for ...
  • Mu Y, Zheng XJ, Yu HQ. Determining Optimum Conditions for ...
  • Montgomery DC. Design and Analysis of Experiments. Publisher: John Wiley ...
  • Metcalf SI. Wastewater Engineering: Treatment, Disposal, Reuse. Newyork: McGraw-Hill. ۲۰۰۳ ...
  • Demim S, DrouicheN, Aouabed A, Benayad T, Couderchet M, Semsari ...
  • Ghanim AN. Application of Response Surface Methodology to Optimize Nitrate ...
  • Nawarkar CJ, Salkar VD. Solar Powered Electrocoagulation System for Municipal ...
  • Garg KK, Prasad B. Development of Box Behnken Design for ...
  • Cañizares P, Jiménez C, Martínez F, Sáez C, Rodrigo MA. ...
  • Rahmani A. Survey of Electrocoagulation Process for COD Removal from ...
  • Gao S, Yang J, Tian J, Ma F, Tu G, ...
  • Barrera-Díaz C, Bilyeu B, Roa G, Bernal-Martinez L. Physicochemical Aspects ...
  • Barrera Díaz CE, González-Rivas N. The Use of Al, Cu, ...
  • Safari S, Azadi Aghdam M, Kariminia HR. Electrocoagulation for COD ...
  • Emamjomeh MH, Sivakumar M. Review of Pollutants Removal by Electrocoagulation ...
  • نمایش کامل مراجع