Studying the effect of backgrounds on the determination of radiative thermal neutron capture cross-section in the Neutron Powder Diffraction facility of the Tehran Research Reactor
Publish place: Radiation Physics and Engineering، Vol: 4، Issue: 2
Publish Year: 1402
نوع سند: مقاله ژورنالی
زبان: English
View: 148
This Paper With 9 Page And PDF Format Ready To Download
- Certificate
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_RPE-4-2_002
تاریخ نمایه سازی: 20 اسفند 1401
Abstract:
Neutron data and cross-sections are highly regarded and are essential for developing nuclear equipment such as advanced fission and fusion reactors, accelerators, neutron shielding, physics studies, etc. The neutron cross-section should preferably be measured using a single-energy neutron beam, although the presence of a background in research reactors can affect its accurate determination. The Neutron Powder Diffraction (NPD) facility of Tehran Research Reactor (TRR) has been taken into consideration for measuring the neutron cross-section based on its properties, including neutron monochromator and multiple collimators. In this work, radiative capture cross-sections of Au, In, and Rh materials have been calculated using TRR monochromatic beam. MCNPX is a Monte Carlo particle transport code that has been applied to simulate the measurement system of the neutron cross-section and calculate the reaction rates. The effect of the presence and absence of different sections of the background on the cross-section values was investigated and the results were compared with EXFOR data library for validation. According to the findings, neutron backgrounds can have varying impacts depending on factors such as sample material, the isotope resonance regions, neutron source spatial distribution, and neutron monochromatic energy. However, the presence of fast neutron background contributes to the most uncertainty in the cross section values while its removal produces an average discrepancy from experimental libraries of ۷.۱۶%. Also, removing the cold neutron background also causes a relative difference equal to ۷.۶۵%.
Keywords:
Authors
Mahya Pazoki
Department of Radiation Application, Shahid Beheshti University, Tehran, Iran
Hamid Jafari
Department of Radiation Application, Shahid Beheshti University, Tehran, Iran
Zohreh Gholamzadeh
Reactor and Nuclear Safety, Nuclear Science and Technology Research Institute, Atomic Energy Organization of Iran, Tehran, Iran
مراجع و منابع این Paper:
لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :