A Study on Performance and Safety Tests of Defibrillator Equipment

Publish Year: 1396
نوع سند: مقاله ژورنالی
زبان: English
View: 48

This Paper With 6 Page And PDF Format Ready To Download

  • Certificate
  • من نویسنده این مقاله هستم

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این Paper:

شناسه ملی سند علمی:

JR_JBPE-7-4_009

تاریخ نمایه سازی: 30 دی 1402

Abstract:

Introduction: Nowadays, more than ۱۰,۰۰۰ different types of medical devices can be found in hospitals. This way, medical electrical equipment is being employed in a wide variety of fields in medical sciences with different physiological effects and measurements. Hospitals and medical centers must ensure that their critical medical devices are safe, accurate, reliable and operational at the required level of performance. Defibrillators are critical resuscitation devices. The use of reliable defibirillators has led to more effective treatments and improved patient safety through better control and management of complications during Cardiopulmonary Resuscitation (CPR).Materials and Methods: The metrological reliability of twenty frequent use, manual defibrillators in use ten hospitals (۴ private and ۶ public) in one of the provinces of Iran according to international and national standards was evaluated.Results: Quantitative analysis of control and instrument accuracy showed the amount of the obtained results in many units are critical which had less value over the standard limitations especially in devices with poor battery. For the accuracy of delivered energy analysis, only twelve units delivered acceptable output values and the precision in the output energy measurements especialy in weak battry condition, after activation of discharge alarm, were low. Conclusion: Obtained results indicate a need for new and severe regulations on periodic performance verifications and medical equipment quality control program especially for high risk instruments. It is also necessary to provide training courses on the fundumentals of operation and performane parameters for medical staff in the field of meterology in medicine and how one can get good accuracy results especially in high risk medical devices.

Authors

A Tavakoli Golpaygani

Department of Biomedical Engineering, Standard Research Institiute, Karaj, Iran

M M Movahedi

Department of Medical Physics, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran

M Reza

Department of Electrical Engineering, Iranian Research Organization for Science and Technology (IROST), Tehran, Iran

مراجع و منابع این Paper:

لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :
  • Trayanova N. Defibrillation of the heart: insights into mechanisms from ...
  • Hutton P, Cooper GM, James FM. Fundamental principles and practice ...
  • Gad SC. Safety evaluation of medical devices. Boca Raton: CRC ...
  • Khandpur RS. Handbook of biomedical instrumentation. Navrangpura: Tata McGraw-Hill Education; ...
  • Street LJ. Introduction to biomedical engineering technology. Boca Raton: CRC ...
  • A Study on Performance and Safety Tests of Electrosurgical Equipment [مقاله ژورنالی]
  • In: UL. International Electrotechnical Commission. IEC ۶۰۶۰۱-۱-۱, Medical Electrical Equipment- ...
  • In: IEC. International Electrotechnical Commission. IEC ۶۰۶۰۱-۲-۴, Medical electrical equipment ...
  • نمایش کامل مراجع