Seismic Retrofit of Rectangular Concrete Columns with Splice Deficiencies by External Prestressing
Publish Year: 1382
Type: Conference paper
Language: English
View: 2,171
This Paper With 8 Page And PDF Format Ready To Download
- Certificate
- I'm the author of the paper
Export:
Document National Code:
SEE04_SS15
Index date: 1 November 2005
Seismic Retrofit of Rectangular Concrete Columns with Splice Deficiencies by External Prestressing abstract
Experimental research has been conducted to investigate the effectiveness of external prestressing as a seismic retrofit methodology for reinforced concrete bridge columns. The retrofit technique involves external prestressing concrete columns in transverse direction to improve their seismic performance.Rectangular columns with spliced longitudinal reinforcement have been tested with and without seismic retrofitting. It was observed that external prestressing improved bond between concrete and reinforcement in the splice region and resulted in improvements in inelastic column deformability. The paper outlines the experimental program employed and the test results obtained.
Seismic Retrofit of Rectangular Concrete Columns with Splice Deficiencies by External Prestressing authors
Majid Sadoughi Yarandi
Doctoral Candidate, Department of Civil Engineering, University of Ottawa, Ottawa, Canada
Murat Saatcioglu
Professor, Department of Civil Engineering, University of Ottawa, Ottawa, Canada,