Dosimetry of Total Body Irradiation with human phantom

Publish Year: 1387
نوع سند: مقاله کنفرانسی
زبان: English
View: 1,953

متن کامل این Paper منتشر نشده است و فقط به صورت چکیده یا چکیده مبسوط در پایگاه موجود می باشد.
توضیح: معمولا کلیه مقالاتی که کمتر از ۵ صفحه باشند در پایگاه سیویلیکا اصل Paper (فول تکست) محسوب نمی شوند و فقط کاربران عضو بدون کسر اعتبار می توانند فایل آنها را دریافت نمایند.

  • Certificate
  • من نویسنده این مقاله هستم

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این Paper:

شناسه ملی سند علمی:

ICMEDICALP08_033

تاریخ نمایه سازی: 19 شهریور 1387

Abstract:

Total Body Irradiation (TBI) is used to prepare patients for Bone Marrow Transplantation (BMT) for the treatment of some diseases such as leukemia, lymphoma and etc. there is no standard technique, as departments adopt their own treatment aims and also influenced by the type of treatment machine available . The purposes of this study were (1) to measure some basic dosimetric data in TBI condition in order to check accuracy in dose delivery to the prescribed point (ambilicus). (2) To develop an algorithm for midplane dose determination in TBI techniques. (3) To investigate dose homogeneity through whole body in TBI condition . Materials and methods: in our study some basic dosimetric data was measured with a water phantom (30×30×30 cm3) and a Farmer ionization chamber (0.6 cc) which connected to a UNIDOSE electrometer. To check accuracy in midplane dose determination through proposed algorithm and to investigate dose homogeneity through whole body a human phantom and four silicon diodes type-p which were connected to the MULTIDOS electrometer were used. A proper lung shield was made to reduce lung’s dose. In addition a TBI stand with dimensions of 70×100× 210 cm3 was built for supporting shields and patients . Results: the results based on the measurement of basic dosimetric data showed that the accuracy in dose delivery to the prescribed point was 2.9%. From diode measurements it can be seen that the accuracy of the proposed algorithm for midplane dose determination was within 3.5%. The results of measured surface doses for human phantom implied that dose homogeneity at anterior surface was ±6% and at posterior surface was ±5% of the prescribed dose. The delivered dose to the lung was 14.4 Gy and it was reduced to 8.16 Gy by applying the proper lung shield . Discussion: the obtained accuracy and variation of the delivered dose to the prescribed point was within 3% which is considered to be clinically acceptable. The proposed algorithm by this work appears to be useful in TBI treatment. The obtained homogeneity through whole body was within ±6%. In our opinion this level of homogeneity is acceptable. By the notice of achieved accuracy and dose homogeneity it is recommended that TBI treatment can be implemented in our center treatment cancer (Imam Khomeiny Hospital

Authors

Gh. Geraily

PHD student of IUMS, Tehran

M. Allahverdi

PhD, Associate professor of medical physics department of TUMS, Tehran

M Esfehani

Esfehani. Mahbod, Msc, Associate dosimetrist of radiotherapeutic oncology department of cancer institute, Tehran

A. Sharafi

Sharafi. Aliakbar, PhD, Assistant professor of radiology department of Iran University, Tehran