Advanced Analysis of PRVEP in Anisometropic Amblyopia
Publish place: Iranian Journal of Medical Physics، Vol: 15، Issue: 3
Publish Year: 1397
نوع سند: مقاله ژورنالی
زبان: English
View: 473
This Paper With 10 Page And PDF Format Ready To Download
- Certificate
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_IJMP-15-3_004
تاریخ نمایه سازی: 18 تیر 1398
Abstract:
Introduction: to identify the pattern-reversal visual evoked potential (PRVEP) waveform descriptor by evaluating discrete wavelet transform (DWT) in order to optimize stimulus in the diagnosis of anisometropia amblyopia. Materials and Methods: The PRVEP testing was performedfor 31 normal individuals and 35 patients with amblyopia. The stimuli were consisted of spatial frequencies of 1, 2, and 4 cycles per degree (cpd) and contrast levels of 100%, 50%, 25%, and 5%. The results were analyzed in the dimensions of time and time-frequency. DWT descriptor were extracted at level 7 (7P descriptor) for Haar, Daubechies 2, Daubechies 4, Symlet 5, Biorthogonal 3.5, Biorthogonal 4.4, and Coiflet 5 wavelets for 12 stimuli and compared between the two groups. The correlation between different spatial frequencies at the same contrast level and the similarities between reconstructed signals and original waveforms were evaluated. Results: There were a significant reduction in P100 amplitude and a significant elevation in latency among the patient group. In the patients with amblyopia, 7P descriptor decreased in all analysis except for the frequency of 4 cpd and the contrast of 5% using bior4.4. No significant correlation was observed between different frequencies at a special contrast; however, there was a significant correlation between reconstructed signals and the original ones. Conclusion: The 7P descriptor could be used to distinguish between normal and abnormal signals in anisometropia amblyopia. Considering the results, DWT with coif5, db4, bior4.4, and bior3.5 wavelets can be utilized as a good indicator for selecting optimum stimulus.
Keywords:
Authors
Homa Hassankarimi
Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran, Iran
Ebrahim Jafarzadehpur
Iran University of Medical Sciences
Alireza Mohamadi
Department of Optometry, School of Rehabilitation Science, Iran University of Medical Sciences, Tehran, Iran
Seyed Noori
Departments of Medical Physics and Biomedical Engineering, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran
مراجع و منابع این Paper:
لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :