The Efficiency of Polyaluminum Silicate Chloride Coagulants in Nickel Removal from Aqueous Solutions

Publish Year: 1401
نوع سند: مقاله ژورنالی
زبان: English
View: 106

This Paper With 8 Page And PDF Format Ready To Download

  • Certificate
  • من نویسنده این مقاله هستم

استخراج به نرم افزارهای پژوهشی:

لینک ثابت به این Paper:

شناسه ملی سند علمی:

JR_AHS-11-4_004

تاریخ نمایه سازی: 27 خرداد 1402

Abstract:

Background & Aims: Nickel is one of the toxic heavy metals naturally released into the environment through industrial activities. Coagulation and flocculation are one of the available heavy metal removal methods, but experience has shown that high pH and the addition of coagulant aid are usually required to remove nickel by coagulation and flocculation process. This study aimed to examine the efficiency of polyaluminum silicate chloride (PASiC) coagulant in nickel removal from aqueous solutions. Materials and Methods: This study was conducted experimentally on a laboratory scale using the standard jar testing method. We investigated the effect of pH parameters (۴-۱۱), amount of coagulant (۷.۵-۷۵ mg/L based on aluminum), initial metal concentration (۱۰-۴۰۰ mg/L), and settling time (۱۵-۹۰ minutes). Nickel concentration was measured by flame atomic absorption spectroscopy. In this study, t test, between-groups ANOVA, and regression were used for analysis. Results: Results showed that the removal efficiency decreased at higher concentrations of nickel metal. Furthermore, increasing the settling time beyond ۳۰ minutes did not significantly change the removal efficiency. PASiC had a removal efficiency of over ۹۹% at an optimum pH of ۸, an optimum PASiC concentration of ۱۵ mg/L, an optimum time of ۳۰ minutes, and a nickel concentration of ۱۰-۱۰۰ mg/L. Conclusion: According to the results, the use of PASiC as a coagulant is a suitable option for removing nickel from polluted wastewater.

Authors

Mohammad javad Mohammadi

Environmental Technologies Research Center, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran. Department of Environmental Health Engineering, Faculty of Health, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran

Afshin Takdastan

Environmental Technologies Research Center, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran. Department of Environmental Health Engineering, Faculty of Health, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran

Mehdi Zhoolanezhad

Department of Environmental Health Engineering, Environmental Technologies Research Center, Faculty of Health, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran

Abdolkazem Neisi

Environmental Technologies Research Center, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran. Department of Environmental Health Engineering, Faculty of Health, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran

مراجع و منابع این Paper:

لیست زیر مراجع و منابع استفاده شده در این Paper را نمایش می دهد. این مراجع به صورت کاملا ماشینی و بر اساس هوش مصنوعی استخراج شده اند و لذا ممکن است دارای اشکالاتی باشند که به مرور زمان دقت استخراج این محتوا افزایش می یابد. مراجعی که مقالات مربوط به آنها در سیویلیکا نمایه شده و پیدا شده اند، به خود Paper لینک شده اند :
  • Mehdizadeh S, Sadjadi S, Ahmadi SJ, Outokesh M. Removal of ...
  • Johnson PD, Girinathannair P, Ohlinger KN, Ritchie S, Teuber L, ...
  • Cempel M, Nikel G. Nickel: a review of its sources ...
  • Kurniawan TA, Chan GY, Lo W-H, Babel S. Physico–chemical treatment ...
  • Mahvi A, Malakootian M, Heidari M. Comparison of polyaluminum silicate ...
  • Miner G. Standard methods for the examination of water and ...
  • Bakar AFA, Halim AA, editors. Treatment of automotive wastewater by ...
  • نمایش کامل مراجع