Evaluation of Friction Damper Device Effect on Structural Response under Blast Loads
Publish Year: 1396
نوع سند: مقاله ژورنالی
زبان: English
View: 509
This Paper With 7 Page And PDF Format Ready To Download
- Certificate
- من نویسنده این مقاله هستم
استخراج به نرم افزارهای پژوهشی:
شناسه ملی سند علمی:
JR_CRPASE-3-2_005
تاریخ نمایه سازی: 27 مرداد 1397
Abstract:
The increase in the number of terrorist attacks especially in the last few years has shown that the effect of blast loads on structures is a serious matter that should be considered in the important structure design process. Decreasing the damages that can be caused by the explosion is the main purpose of many researches. This paper evaluates the structural response under blast loads. Three moment frames with 3, 6 and 8 stories equipped with the mentioned damper are investigated under blast load and dynamic behaviors of them have been evaluated. The effect of strain rate for steel material also considered. The response of frames with and without dampers is compared in terms of inter-story drifts, maximum floor displacements and base shear. It is found that response of the structures can be reduced dramatically using friction dampers. Moreover, the reduction percentage of roof displacement of frames will be decreased by increasing the number of stories
Keywords:
Authors
Ghasem Dehghani Ashkezari
Department of Civil Engineering, Malek Ashtar University of Technology, Tehran, Iran
Mojtaba Naeej
Department of Civil Engineering, Babol University of Technology, Babol, Iran